Message type: E = Error
Message class: PMMO_PEGGING - Messages for Pegging in PMMO
Message number: 101
Message text: Grouping WBS element &2 requires &1 to be included in the current run
The selected grouping &V2& has a related higher-level grouping &V1&.
However, &V1& is not included in the pegging run.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Include &V1& on the selection screen of the pegging report.
Error message extract from SAP system. Copyright SAP SE.
PMMO_PEGGING101
- Grouping WBS element &2 requires &1 to be included in the current run ?The SAP error message PMMO_PEGGING101 typically occurs in the context of production planning and materials management, particularly when dealing with pegging and the assignment of requirements to specific production orders or projects. This error indicates that a specific Work Breakdown Structure (WBS) element requires a certain component or material to be included in the current run for processing.
Cause: The error is generally caused by one of the following reasons: Missing Component: The required component or material (indicated by &1) is not included in the current planning run for the specified WBS element (indicated by &2). Planning Configuration: There may be issues with the configuration of the planning parameters or settings that prevent the system from recognizing the required components. Data Inconsistencies: There could be inconsistencies in the master data, such as the WBS element not being properly linked to the required materials or components.
Solution: To resolve the PMMO_PEGGING101 error, you can take the following steps: Check
Get instant SAP help. Sign up for our Free Essentials Plan.
PMMO_PEGGING044
Missing master data for underpegged WBS - grouping WBS &1, MRP area &2
What causes this issue? Missing master data for underpegged WBS element for account assignment group &V1& and MRP area &V2&.System Re...
PMMO_PEGGING043
Replenishment elem. &2 not pegged because no assignments found for NHA &1
What causes this issue? The replenishment element &v2& was not pegged because no assignments were found for the next higher assembly &v1&...
PMMO_PEGGING102
No valid material number was found for the selection
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
PMMO_PEGGING103
In procurement: recursive assignment for replenishment element &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.