Message type: E = Error
Message class: /PMG/GE_ENH -
Message number: 069
Message text: User: &, defaulted for Dual control NOT authorized to execute mass change
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
/PMG/GE_ENH069
- User: &, defaulted for Dual control NOT authorized to execute mass change ?The SAP error message
/PMG/GE_ENH069 User: &, defaulted for Dual control NOT authorized to execute mass change
typically indicates that a user is attempting to perform a mass change operation in a system that has dual control enabled, but the user does not have the necessary authorizations to execute that operation.Cause:
- Dual Control Configuration: The system is configured to require dual control for certain operations, meaning that two users must approve or execute certain actions to ensure security and compliance.
- User Authorization: The user attempting the mass change does not have the required authorization roles or permissions to perform the action under the dual control settings.
- User Role Assignment: The user may not be assigned to the appropriate roles that allow them to execute mass changes in the system.
Solution:
Check User Authorizations:
- Review the user’s roles and authorizations in the SAP system. Ensure that the user has the necessary permissions to perform mass changes.
- Use transaction code
SU01
to check the user’s profile and assigned roles.Review Dual Control Settings:
- Check the configuration of dual control settings in the system. This can typically be done in the relevant customizing transaction (e.g.,
SPRO
).- Ensure that the dual control settings are correctly configured and that the user is part of the required approval workflow.
Assign Appropriate Roles:
- If the user lacks the necessary roles, work with your SAP security team to assign the appropriate roles that include mass change permissions.
- Ensure that the user is also assigned to any necessary approval roles if dual control is in place.
Testing:
- After making changes to the user’s roles or authorizations, have the user log out and log back in to ensure that the changes take effect.
- Attempt the mass change operation again to verify that the issue has been resolved.
Consult Documentation:
- Refer to SAP documentation or help resources for specific details on dual control configurations and required authorizations for mass changes.
Related Information:
SU01
- User MaintenancePFCG
- Role MaintenanceSPRO
- Customizing Implementation GuideBy following these steps, you should be able to identify the cause of the error and implement a solution to allow the user to perform the mass change operation successfully.
Get instant SAP help. Start your 7-day free trial now.
/PMG/GE_ENH068
Only 1 implementation should exist for BADI /PMG/GE_MDL_DUALCTRL_ACT_BADI
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/PMG/GE_ENH067
Dual Control Active, Work Flow triggered for user: & (&)
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/PMG/GE_ENH070
No user maintained for dual control in BADI /PMG/GE_MDL_DUALCTRL_ACT_BADI
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/PMG/GE_ENH071
Workflow could not be triggered, contact system administrator.
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.