Do you have any question about this error?
Message type: E = Error
Message class: /PLMI/RCA_CALC -
Message number: 091
Message text: Total solids value is negative for output stream &1
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
/PLMI/RCA_CALC091
- Total solids value is negative for output stream &1 ?The SAP error message
/PLMI/RCA_CALC091 Total solids value is negative for output stream &1
typically occurs in the context of the SAP Process Integration (PI) or SAP Advanced Planning and Optimization (APO) modules, particularly when dealing with calculations related to material properties or process streams.Cause:
The error indicates that the total solids value calculated for a specific output stream is negative. This can happen due to several reasons, including:
- Data Entry Errors: Incorrect or incomplete data entries in the relevant master data or transaction data can lead to negative values.
- Calculation Errors: Issues in the calculation logic or formulas used to derive the total solids value may result in negative outputs.
- Configuration Issues: Incorrect configuration settings in the system that affect how total solids are calculated or reported.
- Material Properties: The properties of the materials involved may not be defined correctly, leading to unrealistic calculations.
Solution:
To resolve this error, you can take the following steps:
Check Input Data: Review the input data for the output stream in question. Ensure that all relevant values (e.g., mass, volume, concentration) are entered correctly and are within expected ranges.
Review Calculation Logic: If you have access to the calculation logic or formulas, verify that they are correctly implemented and that there are no errors in the logic that could lead to negative values.
Validate Material Master Data: Ensure that the material master data for the materials involved in the calculation is complete and accurate. Check properties such as density, composition, and other relevant parameters.
Configuration Review: If applicable, review the configuration settings related to the calculation of total solids. Ensure that they are set up correctly according to business requirements.
Consult Documentation: Refer to SAP documentation or notes related to the specific module you are working with. There may be known issues or additional guidance available.
Testing: After making corrections, perform tests to ensure that the total solids value is calculated correctly and that the error does not reoccur.
Seek Support: If the issue persists, consider reaching out to your SAP support team or consulting with SAP experts who can provide deeper insights into the problem.
Related Information:
By following these steps, you should be able to identify the root cause of the error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
/PLMI/RCA_CALC090
Total solids value is greater than the quantity for primary output &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/PLMI/RCA_CALC089
Total solids value is negative for primary output &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/PLMI/RCA_CALC092
Total solids value is greater than the quantity for output stream &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/PLMI/RCA_CALC093
Property spec. does not exist; manual composition not allowed for PO
What causes this issue? You have set in Customizing that you want to manually adjust the composition of the primary output. However, this is only pos...
Click on this link to search all SAP messages.