Do you have any question about this error?
Message type: E = Error
Message class: /PLMI/RCA_CALC -
Message number: 089
Message text: Total solids value is negative for primary output &1
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
/PLMI/RCA_CALC089
- Total solids value is negative for primary output &1 ?The SAP error message
/PLMI/RCA_CALC089 Total solids value is negative for primary output &1
typically occurs in the context of the SAP Process Industry (SAP PI) or SAP Production Planning (SAP PP) modules, particularly when dealing with calculations related to production processes, such as in the case of recipes or production orders.Cause:
The error indicates that the total solids value calculated for a primary output (denoted by
&1
, which is a placeholder for the specific output material) is negative. This can happen due to several reasons:
Incorrect Input Data: The input data for the calculation may be incorrect or incomplete. This could include incorrect quantities, wrong material specifications, or missing data in the recipe or production order.
Formula Errors: The formulas used to calculate total solids may have errors or may not be set up correctly in the system.
Negative Values in Components: If any of the components or raw materials used in the calculation have negative values (e.g., due to incorrect inventory data), this can lead to a negative total solids value.
Configuration Issues: There may be issues with the configuration of the material master or the recipe that lead to incorrect calculations.
Solution:
To resolve this error, you can take the following steps:
Check Input Data: Review the input data for the production order or recipe. Ensure that all quantities and specifications are correct and that there are no missing values.
Review Formulas: Check the formulas used for calculating total solids. Ensure that they are set up correctly and that they reference the correct components.
Inspect Component Values: Look at the values of the components used in the calculation. Ensure that none of them have negative values and that they are correctly defined in the material master.
Configuration Review: If the issue persists, review the configuration settings for the material and the recipe. Ensure that all settings are appropriate for the type of production process you are using.
Consult Documentation: Refer to SAP documentation or help resources for specific guidance on the error message and related calculations.
Debugging: If you have access to technical resources, consider debugging the calculation process to identify where the negative value is being introduced.
Contact SAP Support: If you are unable to resolve the issue, consider reaching out to SAP support for assistance, especially if this is a recurring problem.
Related Information:
CO02
(Change Production Order) or C202
(Change Recipe) to review the relevant data.By following these steps, you should be able to identify and resolve the cause of the error message regarding negative total solids values in SAP.
Get instant SAP help. Start your 7-day free trial now.
/PLMI/RCA_CALC088
Total solids cannot be calculated for output stream (stage &1)
What causes this issue? The cause can be one of the following: The total solids mass is zero for the output stream of stage &V1&. There is a ...
/PLMI/RCA_CALC087
Total solids cannot be calculated for primary output &1
What causes this issue? The cause can be one of the following: The total solids mass is zero for the primary output. There is a stage where <ZK>...
/PLMI/RCA_CALC090
Total solids value is greater than the quantity for primary output &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/PLMI/RCA_CALC091
Total solids value is negative for output stream &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.