Do you have any question about this error?
Message type: E = Error
Message class: /PLMI/BO_RSP -
Message number: 020
Message text: Specification &2 cannot be part of itself in &1 listing
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
/PLMI/BO_RSP020
- Specification &2 cannot be part of itself in &1 listing ?The SAP error message
/PLMI/BO_RSP020 Specification &2 cannot be part of itself in &1 listing
typically occurs in the context of SAP Product Lifecycle Management (PLM) or SAP Recipe Management when dealing with specifications, such as materials, recipes, or other objects that have hierarchical relationships.Cause:
This error indicates that there is a circular reference in the specification hierarchy. Specifically, it means that a specification (identified by &2) is being referenced in a way that it is trying to include itself in its own listing or hierarchy (identified by &1). This can happen if:
- A specification is incorrectly set up to reference itself.
- There is a misconfiguration in the specification relationships.
- The user is trying to create a recursive relationship that is not allowed.
Solution:
To resolve this error, you can take the following steps:
Check Specification Relationships:
- Go to the specification in question (using transaction codes like
C202
for specifications).- Review the relationships and dependencies of the specification to ensure that it does not reference itself directly or indirectly.
Correct the Hierarchy:
- If you find that the specification is incorrectly set up, modify the relationships to remove the circular reference.
- Ensure that the hierarchy is logical and does not create loops.
Validate Changes:
- After making changes, validate the specification to ensure that the error no longer occurs.
- You can use the relevant transaction to check the integrity of the specification.
Consult Documentation:
- Refer to SAP documentation or help resources for guidance on setting up specifications correctly.
Seek Help from SAP Support:
- If you are unable to resolve the issue, consider reaching out to SAP support for assistance, especially if this is a recurring problem or if it involves complex specifications.
Related Information:
C202
(Display Material Specification) or C201
(Create Material Specification) to manage specifications.By following these steps, you should be able to identify and correct the cause of the error message, allowing you to proceed with your work in SAP PLM or Recipe Management.
Get instant SAP help. Start your 7-day free trial now.
/PLMI/BO_RSP019
You are not authorized to use class type &1
What causes this issue? You want to maintain specification data that is structured as a class with class type &V1&. However, you are not auth...
/PLMI/BO_RSP018
You are not authorized to change specification &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/PLMI/BO_RSP021
For component type &1 of primary output no explosion stop is defined
What causes this issue? <ZH>Note</>: This warning is only relevant if you have process loss defined. You transferred &V2& data th...
/PLMI/BO_RSP022
Specification does not exist
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.