Do you have any question about this error?
Message type: E = Error
Message class: PLM_AUDIT_APPL - Audit Application
Message number: 070
Message text: Cannot apply changes to audit object &1
The audit component &V1& cannot be processed with this function,
because changes to the master data are not allowed.
The function cannot be executed.
Check the status of the audit component &V1& and change it so that
changes to the master data are allowed. If, for example, the audit is
completed according to the status, reset the completion.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
PLM_AUDIT_APPL070
- Cannot apply changes to audit object &1 ?The SAP error message PLM_AUDIT_APPL070 indicates that there is an issue when trying to apply changes to an audit object in the Product Lifecycle Management (PLM) module. This error typically arises in scenarios where the system is unable to process the changes due to various reasons.
Causes:
- Locked Audit Object: The audit object you are trying to modify may be locked by another user or process.
- Authorization Issues: The user may not have the necessary authorizations to make changes to the audit object.
- Inconsistent Data: There may be inconsistencies or errors in the data associated with the audit object.
- System Configuration: There could be configuration issues in the PLM module that prevent changes from being applied.
- Technical Issues: There may be underlying technical issues, such as database locks or system performance problems.
Solutions:
- Check Locks: Verify if the audit object is locked. You can use transaction code SM12 to check for locks and release them if necessary.
- Review Authorizations: Ensure that the user has the appropriate authorizations to modify the audit object. You can check this using transaction code SU53 to analyze authorization failures.
- Data Consistency Check: Perform a consistency check on the data related to the audit object. This may involve reviewing related documents or entries to ensure they are correct.
- Consult Configuration: Review the configuration settings in the PLM module to ensure they are set up correctly. This may involve consulting with a functional consultant or checking configuration documentation.
- Technical Support: If the issue persists, consider reaching out to your SAP Basis team or technical support for assistance. They can help diagnose any underlying technical issues.
Related Information:
By following these steps, you should be able to identify the cause of the error and apply the appropriate solution. If the problem continues, further investigation may be necessary, potentially involving SAP support.
Get instant SAP help. Start your 7-day free trial now.
PLM_AUDIT_APPL069
The long text for &1 (&2) has not been created/changed
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
PLM_AUDIT_APPL068
Specify a valid language for &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
PLM_AUDIT_APPL071
Requested function cannot be executed on the details screen
What causes this issue? The required function cannot be executed on this details screen.System Response The system will not proceed with the process...
PLM_AUDIT_APPL072
Specify a unique identification for the audit
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.