Do you have any question about this error?
Stop googling SAP errors. Use our Free Essentials plan instead - no credit card needed. Start Now →
Message type: E = Error
Message class: PFQ1 - ADP ITF
Message number: 001
Message text: No record for indicator &1 in table &2
No record corresponds to code&1 in table &2.
The system does not continue with the processing.
Enter the correct code as it exists in the corresponding table:
The <ZK>"Element code ZADIG"</> must exist in table T5F6B,
The <ZK>"Presence/absence incident code "</> must exist in table ADP
PRE.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
PFQ1001
- No record for indicator &1 in table &2 ?The SAP error message PFQ1001 "No record for indicator &1 in table &2" typically indicates that the system is trying to access a specific record in a table that does not exist. This error is often related to configuration issues, particularly in the context of SAP's Personnel Administration (PA) or Payroll modules.
Cause:
- Missing Configuration: The most common cause is that the required configuration for the specific indicator (e.g., a payroll area, wage type, or other relevant data) has not been set up in the corresponding table.
- Data Inconsistency: There may be inconsistencies in the data, such as missing entries or incorrect settings in the relevant tables.
- Custom Development: If there are custom developments or enhancements, they might be trying to access data that has not been properly defined or populated.
- Transport Issues: If the system has recently undergone a transport of changes, the necessary data might not have been transported correctly.
Solution:
Check Configuration: Verify that the necessary configuration for the indicator in question is correctly set up in the relevant customizing tables. This may involve checking:
- Table T5D1 for wage types.
- Table T5P1 for payroll areas.
- Other relevant tables based on the specific indicator mentioned in the error message.
Data Entry: If the required record is missing, you may need to create it manually in the relevant table using transaction codes like SE11 (Data Dictionary) or customizing transactions (e.g., SPRO).
Consistency Check: Run consistency checks in the system to identify any discrepancies in the data. This can often be done through standard SAP reports or tools.
Review Custom Code: If there are custom programs or enhancements, review the code to ensure it is correctly handling the data and not making assumptions about the existence of records.
Transport Validation: If the issue arose after a transport, check the transport logs and ensure that all necessary data was included in the transport request.
Related Information:
If the issue persists after following these steps, it may be beneficial to consult with your SAP Basis or HR module expert for further assistance.
Get instant SAP help. Sign up for our Free Essentials Plan.
PFQ1000
&
What causes this issue? No long text availableSystem Response The system issues an error message and will not allow you to continue with this transa...
PFO_EDT009
Error: Unknown exception has occurred at PFO-RFC interface
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
PFQ1002
Use interface PU12 to convert indicator &
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
PFQ1003
Enter correct format: type &1, length &2, no. decimal places &3
What causes this issue? The data format entered in field <ZK>"Corresponding data"</> is not correct.System Response The system...