Do you have any question about this error?
Stop googling SAP errors. Use our Free Essentials plan instead - no credit card needed. Start Now →
Message type: E = Error
Message class: PBAS_SERVICE - HR Master Data: Service Functions
Message number: 046
Message text: T77S0: CCURE PIDGN not specified
In the settings for table T77S0, you have activated the CCURE PIDSL
switch but you have not stored a specification for CCURE PIDGN. This
means that the system should use the person ID for selection but you
have not specified how the system should build this selection (using
the CCURE PIDGN switch).
The system stops processing.
Contact your system administrator.
Deactivate the CCURE PIDSL switch in table T77S0 or store a valid
specification for the CCURE PIDGN setting in table T77S0.
Error message extract from SAP system. Copyright SAP SE.
PBAS_SERVICE046
- T77S0: CCURE PIDGN not specified ?The SAP error message PBAS_SERVICE046 T77S0: CCURE PIDGN not specified typically relates to issues in the configuration of the SAP system, particularly in the context of the Personnel Administration (PA) or Organizational Management (OM) modules. This error indicates that a specific configuration parameter (CCURE PIDGN) is not set, which is necessary for the system to function correctly.
Cause:
- Missing Configuration: The error suggests that the system is trying to access a configuration that has not been defined. This could be due to a missing entry in the relevant tables or settings in the SAP system.
- Incorrect Customization: If the system has been customized, it’s possible that the customization did not include the necessary parameters or that they were incorrectly set.
- Transport Issues: If the configuration was transported from another system, it might not have been transported correctly, leading to missing entries.
Solution:
Check Configuration:
- Go to the SAP transaction code SPRO (SAP Project Reference Object).
- Navigate to the relevant area for Personnel Administration or Organizational Management.
- Look for the configuration related to CCURE PIDGN and ensure it is properly defined.
Maintain the Required Entries:
- If you find that the CCURE PIDGN is indeed missing, you will need to create or maintain the necessary entries in the relevant configuration tables.
- This may involve defining the necessary organizational units, positions, or other related entities.
Review Transport Requests:
- If the issue arose after a transport, check the transport logs to ensure that all necessary objects were included and correctly imported.
- If something is missing, you may need to re-transport the relevant configuration.
Consult Documentation:
- Review SAP documentation or notes related to the specific error message. SAP Notes can provide insights into known issues and their resolutions.
Contact SAP Support:
- If the issue persists after checking the configuration and transport requests, consider reaching out to SAP Support for further assistance.
Related Information:
By following these steps, you should be able to identify and resolve the issue related to the error message PBAS_SERVICE046 T77S0: CCURE PIDGN not specified.
Get instant SAP help. Sign up for our Free Essentials Plan.
PBAS_SERVICE045
Missing data for personnel number &1& &2&
What causes this issue? The system could not determine any data for infotype &V3& for personnel number &V1& &v2&.System Respo...
PBAS_SERVICE044
Deleting data record &1 would cause inconsistencies
What causes this issue? Changing the validity period or deleting the data record with the key &V1& would cause an inconsistency. A change to ...
PBAS_SERVICE047
Incorrect entry &4 in table &1 for &2 field &3
What causes this issue? In table &V1&, the entry &V4& was stored under the &V2& key in the &V3& field. However, this ...
PBAS_SERVICE048
Inconsistent infotype view for infotype &1
What causes this issue? Inconsistent settings exist for an infotype view in tables T582V and T582W for infotype &V1&.System Response The sys...
Click on this link to search all SAP messages.