Do you have any question about this error?
Message type: E = Error
Message class: PB - PD: Message IDs Org. Management
Message number: 337
Message text: Infotype &: Dialog module & does not exist in TDCT
In infotype 1, during the time from &V2& - &V3&, person &V1& is
assigned to a business area which differs from your assignment in the
organizational structure. A person's business area in the
organizational structure is determined by the business area of the
person's cost center. This is in &V4&.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
PB337
- Infotype &: Dialog module & does not exist in TDCT ?The SAP error message PB337 indicates that there is an issue with a specific infotype and dialog module not being found in the TDCT (Table for Dialog Modules). This error typically arises in the context of HR (Human Resources) modules when the system is trying to access a dialog module that is either not defined or not properly configured.
Cause:
- Missing Infotype: The specified infotype may not exist in the system or may not be properly defined.
- Incorrect Configuration: The dialog module associated with the infotype may not be configured correctly in the system.
- Transport Issues: If the infotype or dialog module was recently transported from another system, there may have been issues during the transport process.
- Custom Development: If there are custom infotypes or dialog modules, they may not have been properly implemented or activated.
Solution:
- Check Infotype Existence: Verify that the infotype exists in the system. You can do this by using transaction code
PA30
(Maintain HR Master Data) and checking if the infotype is available.- Review Configuration: Use transaction code
SPRO
to navigate to the relevant configuration settings for HR and ensure that the dialog module is correctly defined.- Check TDCT Table: Use transaction code
SE11
to view the TDCT table and check if the dialog module for the infotype is listed. If it is missing, you may need to add it or correct the configuration.- Transport Logs: If the issue arose after a transport, check the transport logs for any errors or warnings that may indicate what went wrong during the transport process.
- Custom Code Review: If the infotype or dialog module is custom, review the code to ensure it is correctly implemented and activated.
- SAP Notes: Check the SAP Support Portal for any relevant SAP Notes that may address this specific error or provide guidance on similar issues.
Related Information:
PA30
, SPRO
, SE11
, and SE80
for debugging and configuration.If the problem persists after following these steps, it may be beneficial to consult with your SAP Basis or HR module support team for further assistance.
Get instant SAP help. Start your 7-day free trial now.
PB336
Infotype &: Dialog module and program overlap: & &
What causes this issue? Person &V1& is assigned in infotype 1 to a cost center which differs from your assignment in the organizational struc...
PB335
Infotype &: & & does not exist
What causes this issue? In infotype 1 person &V1& is assigned to a different organizational unit to the one assigned in the organizational st...
PB338
Infotype &: & & does not exist in an active version
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
PB339
Infotype &: & is missing --> Generate using RPUMS40CCI
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.