How To Fix OPS_SE_QUM219 - No inspection methods assigned to Master Inspection Characteristic


SAP Error Message - Details

  • Message type: E = Error

  • Message class: OPS_SE_QUM - Quality Management: Messages for Service Enabling

  • Message number: 219

  • Message text: No inspection methods assigned to Master Inspection Characteristic

  • Show details Hide details


  • Self-Explanatory Message

    Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.

    To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.

    Unfortunately, there isn't any extra information in this error notice.



    What else can you do?

    First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).

    Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.

    You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.


Smart SAP Assistant

  • What is the cause and solution for SAP error message OPS_SE_QUM219 - No inspection methods assigned to Master Inspection Characteristic ?

    The SAP error message OPS_SE_QUM219 indicates that there are no inspection methods assigned to a Master Inspection Characteristic (MIC) in the Quality Management (QM) module. This can occur during the creation or execution of inspection plans, where the system expects to find an inspection method linked to the MIC but does not.

    Cause:

    1. Missing Assignment: The primary cause of this error is that the inspection method has not been assigned to the Master Inspection Characteristic in the system.
    2. Incorrect Configuration: There may be issues with the configuration of the inspection method or the MIC itself.
    3. Data Inconsistency: There could be inconsistencies in the data or settings related to the inspection method or MIC.

    Solution:

    To resolve the OPS_SE_QUM219 error, follow these steps:

    1. Check Master Inspection Characteristic:

      • Go to the transaction code QMP1 (Create Master Inspection Characteristic) or QMP2 (Change Master Inspection Characteristic).
      • Enter the relevant MIC and check if an inspection method is assigned.
    2. Assign Inspection Method:

      • If no inspection method is assigned, you need to assign one. You can do this by:
        • Selecting the MIC and navigating to the "Inspection Method" tab.
        • Assign an appropriate inspection method that matches the requirements of the inspection characteristic.
    3. Create/Modify Inspection Method:

      • If you do not have an appropriate inspection method, you may need to create one using transaction code QMT1 (Create Inspection Method) or modify an existing one using QMT2 (Change Inspection Method).
      • Ensure that the inspection method is correctly configured and meets the specifications needed for the MIC.
    4. Check Inspection Plan:

      • If the error occurs while working with an inspection plan, ensure that the inspection plan is correctly linked to the MIC and that the MIC has the necessary inspection methods assigned.
    5. Validate Data:

      • Ensure that all related data (like material master, inspection lot, etc.) is consistent and correctly set up.
    6. Testing:

      • After making the necessary changes, test the process again to ensure that the error no longer occurs.

    Related Information:

    • Transaction Codes:

      • QMP1 - Create Master Inspection Characteristic
      • QMP2 - Change Master Inspection Characteristic
      • QMT1 - Create Inspection Method
      • QMT2 - Change Inspection Method
      • QMP3 - Display Master Inspection Characteristic
    • Documentation: Refer to SAP Help documentation for Quality Management for detailed information on MICs and inspection methods.

    • User Roles: Ensure that you have the necessary authorizations to create or modify MICs and inspection methods.

    By following these steps, you should be able to resolve the OPS_SE_QUM219 error and ensure that your inspection methods are properly assigned to the Master Inspection Characteristics in SAP.

    • Do you have any question about this error?


      Upgrade now to chat with this error.


Instant HelpGet instant SAP help. Start your 7-day free trial now.


Related SAP Error Messages

Click the links below to see the following related messages:

Click on this link to search all SAP messages.