Message type: E = Error
Message class: OIUPR - PRA Production Messages
Message number: 758
Message text: Summing system input to calculate ratios for network adjustments
System input volumes for this network (gathered from allocation and/or
production and/or theoretical meters, and/or well completions) totaled
zero
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
OIUPR758
- Summing system input to calculate ratios for network adjustments ?The SAP error message OIUPR758 typically relates to issues encountered during the processing of network adjustments in the SAP system, particularly in the context of the Oil and Gas industry or similar sectors where network calculations are performed. This error indicates that there is a problem with summing system input to calculate ratios for network adjustments.
Cause: Data Inconsistency: The error may arise due to inconsistencies in the data being processed. This could be due to missing or incorrect entries in the relevant master data or transaction data.
Configuration Issues: Incorrect configuration settings in the network adjustment parameters or related modules can lead to this error. Calculation Logic: There may be issues in the calculation logic that is used to derive the ratios for network adjustments, possibly due to changes in the underlying data structure or business rules. Missing Input Data: If the system lacks the necessary input data to perform the calculations, it may
Get instant SAP help. Sign up for our Free Essentials Plan.
OIUPR757
Upstrm config at listed node could potentially cause adjustment problems
What causes this issue? Multiple non-allocation, non-theoretical, non-deduct, and non-well/wc nodes exist at the level upstream of the listed node. T...
OIUPR756
FATAL: CALCULATING TOLERANCE FOR GAS PLANT ADJUSTED PRODUCTION
What causes this issue? THE SYSTEM INPUT VOLUMES IN THE NETWORK (GATHERED FROM POINTS DOWNSTREAM OF THE PLANT INLET (S) OR TOP LEVEL METERS) TOTALED ...
OIUPR759
Adjusted theoretical was not calculated for listed well/wc
What causes this issue? Producing well/well completion has been calculated as 0, even after accounting for dependent material/vt allocations.System ...
OIUPR760
The listed MP contains all deduct meters immediately upstream
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.