Message type: E = Error
Message class: OIUPR - PRA Production Messages
Message number: 757
Message text: Upstrm config at listed node could potentially cause adjustment problems
Multiple non-allocation, non-theoretical, non-deduct, and non-well/wc
nodes exist at the level upstream of the listed node.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
OIUPR757
- Upstrm config at listed node could potentially cause adjustment problems ?The SAP error message OIUPR757 indicates that there is a potential issue with the upstream configuration at a specified node, which could lead to adjustment problems in the system. This error typically arises in the context of SAP's Oil and Gas or Utilities modules, where upstream processes and configurations are critical for accurate data processing and reporting.
Cause: The error can be caused by several factors, including: Incorrect Configuration: The upstream configuration for the specified node may not be set up correctly, leading to inconsistencies in data processing. Missing Data: Required data or parameters for the upstream configuration might be missing or incomplete. Incompatible Settings: There may be incompatible settings between different nodes or configurations that affect the upstream processes. Changes in Business Processes: If there have been recent changes in business processes or system upgrades, the existing configurations may no longer be valid.
Solution: To resolve the OIUPR757 error, consider the following steps: Review Configuration: Check the upstream
Get instant SAP help. Sign up for our Free Essentials Plan.
OIUPR756
FATAL: CALCULATING TOLERANCE FOR GAS PLANT ADJUSTED PRODUCTION
What causes this issue? THE SYSTEM INPUT VOLUMES IN THE NETWORK (GATHERED FROM POINTS DOWNSTREAM OF THE PLANT INLET (S) OR TOP LEVEL METERS) TOTALED ...
OIUPR755
Alloc system-output is less than 0 when adj top lvl mtr at alloc/theo mtr
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIUPR758
Summing system input to calculate ratios for network adjustments
What causes this issue? System input volumes for this network (gathered from allocation and/or production and/or theoretical meters, and/or well comp...
OIUPR759
Adjusted theoretical was not calculated for listed well/wc
What causes this issue? Producing well/well completion has been calculated as 0, even after accounting for dependent material/vt allocations.System ...
Click on this link to search all SAP messages.