Message text: WARNING: A & SPLIT ENCOUNTERED WHEN SUMMING THEO VOLS FOR A DEPENDENCY
WHEN SUMMING THEORETICAL VOLUMES FOR A DEPENDENCY, A DOWNSTREAM SPLIT
WAS ENCOUNTERED. THE VOLUME FOUND AT THE SPLIT WILL OVERRIDE THE
THEORETICAL AT THE MEASUREMENT POINT INDICATED.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
OIUPR746
- WARNING: A & SPLIT ENCOUNTERED WHEN SUMMING THEO VOLS FOR A DEPENDENCY ?The SAP error message OIUPR746, which states "WARNING: A & SPLIT ENCOUNTERED WHEN SUMMING THEO VOLS FOR A DEPENDENCY," typically occurs in the context of SAP's Oil and Gas (O&G) module, particularly when dealing with production volumes and dependencies in the system.
Cause:
This warning indicates that there is a split in the theoretical volumes when the system is trying to sum them for a dependency. This can happen due to several reasons, including:
- Data Inconsistencies: There may be inconsistencies in the data related to production volumes, such as overlapping or conflicting entries.
- Configuration Issues: The configuration settings for dependencies or volume calculations may not be set up correctly.
- Incorrect Dependency Setup: The dependencies defined in the system may not align with the actual production data, leading to splits in the calculations.
- Multiple Sources: If there are multiple sources of data for the same dependency, it can lead to discrepancies in the summed volumes.
Solution:
To resolve this warning, you can take the following steps:
- Review Dependency Configuration: Check the configuration of the dependencies in the system to ensure they are set up correctly and align with the actual production data.
- Data Validation: Validate the production volume data for inconsistencies. Look for overlapping entries or conflicting data that may cause the split.
- Adjust Volume Entries: If you find any discrepancies in the volume entries, correct them to ensure that they are consistent and accurate.
- Consult Documentation: Refer to SAP documentation or help resources specific to the Oil and Gas module for guidance on handling dependencies and volume calculations.
- Run Reports: Use relevant reports to analyze the production volumes and dependencies to identify where the splits are occurring.
- Seek Support: If the issue persists, consider reaching out to SAP support or your internal SAP team for further assistance.
Related Information:
By following these steps, you should be able to address the warning and ensure that your volume calculations are accurate and consistent.
Get instant SAP help. Start your 7-day free trial now.
OIUPR745
WARNING: THE ADJUSTED THEORETICAL QUANTITY IS NEGATIVE
What causes this issue? MORE VOLUME HAS BEEN ALLOCATED TO THIS FUNCTION THAN ITS THEORETICAL HAD INDICATED IT WAS CAPABLE OF RECEIVINGSystem Response...
OIUPR740
FATAL: POTENTIAL FOR DISPOSITION AND THE FORMATION PRODUCTION COLUMN &
What causes this issue? GAS PRODUCT CODE IS NOT, THE POTENTIAL FOR DIFFERENCES BETWEEN THE SUM OF THE DISPOSITION COLUMN AND THE FORMATION PRODUCTIO...
OIUPR749
FATAL: GAS PLANT ERROR
What causes this issue? EITHER 1) A WELL OR PRODUCTION METER WAS FOUND ON THE SAME LEVEL AS A THEORETICAL OR ALLOCATION METER OR 2) A WC OR A MP OTHE...
OIUPR750
Invalid DN configuration
What causes this issue? The processed DN contained one of the following configurations: 1) a wl/wc was not found on the same level as a theoretical ...
Click on this link to search all SAP messages.