Message type: E = Error
Message class: OIUPR - PRA Production Messages
Message number: 734
Message text: WARNING: THE EXTRACTION LOSS FACTOR RECORD WAS NOT WRITTEN.
THE CALCULATED PRODUCTION WAS CALCULATED TO BE 0 AFTER MULTIPLYING BY
THE USER ENTERED EXTRACTION LOSS FACTOR
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
OIUPR734
- WARNING: THE EXTRACTION LOSS FACTOR RECORD WAS NOT WRITTEN. ?The SAP error message OIUPR734, which states "WARNING: THE EXTRACTION LOSS FACTOR RECORD WAS NOT WRITTEN," typically occurs in the context of the SAP Oil and Gas (SAP OIL) module, particularly when dealing with production and extraction data.
Cause: This warning usually indicates that there was an issue with writing the extraction loss factor record during a data processing operation. The potential causes for this warning can include: Missing Configuration: The extraction loss factor may not be properly configured in the system. Data Integrity Issues: There may be inconsistencies or missing data in the records that are required for the extraction loss factor. Authorization Issues: The user may not have the necessary permissions to write records in the relevant tables. System Errors: There could be temporary system issues or bugs that prevent the record from being written.
Solution: To resolve the OIUPR734 warning, you can take the following steps: Check Configuration: Ensure that the extraction loss factor is correctly
Get instant SAP help. Sign up for our Free Essentials Plan.
OIUPR733
WARNING: THE EXTRACTION LOSS FACTOR RECORD WAS NOT WRITTEN.
What causes this issue? THE CALCULATED PRODUCTION WAS CALCULATED TO BE 0 AFTER MULTIPLYING BY 1.1System Response The system issues an error message ...
OIUPR732
FATAL: THE TOTAL DISPOSITION VOL AT THIS MP WAS NOT ALLOCATED TO WELLS
What causes this issue? THE TOTAL DISPOSITION VOLUME AT THIS MEASUREMENT POINT WAS NOT ALLOCATED TO THE WELLS THAT SUPPORTED IT, OR NO WELLS SUPPORT ...
OIUPR738
FATAL: DEPENDENT MATERIAL - MUST BE SPECIFIED WHEN & CO2 OR NITROGEN
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIUPR739
WARNING: NGL COMPONENT VOL WAS ENCOUNTERED THAT CAN NOT BE ALLOCATED
What causes this issue? AN NGL COMPONENT VOLUME WAS ENCOUNTERED THAT CAN NOT BE ALLOCATED USING THE 'COMPGMP' PLANT ALLOCATION METHODSystem...
Click on this link to search all SAP messages.