Do you have any question about this error?
Message type: E = Error
Message class: OIUPR - PRA Production Messages
Message number: 732
Message text: FATAL: THE TOTAL DISPOSITION VOL AT THIS MP WAS NOT ALLOCATED TO WELLS
THE TOTAL DISPOSITION VOLUME AT THIS MEASUREMENT POINT WAS NOT
ALLOCATED TO THE WELLS THAT SUPPORTED IT, OR NO WELLS SUPPORT THIS
ALLOCATION. CHECK AUTOFLOW FLAG FOR PC/VT. THE QUANTITY GIVEN IS THE
AMOUNT THAT WAS ALLOCATED.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
OIUPR732
- FATAL: THE TOTAL DISPOSITION VOL AT THIS MP WAS NOT ALLOCATED TO WELLS ?The SAP error message OIUPR732, which states "FATAL: THE TOTAL DISPOSITION VOL AT THIS MP WAS NOT ALLOCATED TO WELLS," typically occurs in the context of SAP's Oil and Gas (O&G) module, particularly when dealing with production and allocation processes. This error indicates that the total volume of product (disposition volume) at a measurement point (MP) has not been properly allocated to the respective wells.
Cause:
Missing Allocation Data: The most common cause is that the system does not have the necessary allocation data for the wells associated with the measurement point. This could be due to missing or incorrect configuration in the allocation setup.
Incorrect Measurement Point Configuration: The measurement point may not be correctly configured to link to the wells, or the allocation rules may not be set up properly.
Data Entry Errors: There may be errors in the data entry process, such as incorrect volumes being entered or missing entries.
Timing Issues: The error may also arise if the allocation process is being executed before the necessary data has been fully processed or updated in the system.
Solution:
Check Allocation Configuration: Review the allocation configuration for the measurement point. Ensure that the measurement point is correctly linked to the wells and that the allocation rules are properly defined.
Verify Data Entry: Check the data entries for the measurement point and the associated wells. Ensure that all necessary volumes are entered and that there are no discrepancies.
Run Allocation Process: If the allocation process has not been run, or if it was interrupted, try running it again. Ensure that all prerequisite data is available before executing the allocation.
Review Logs and Messages: Check the logs and any additional error messages that may provide more context about the issue. This can help identify if there are other underlying problems.
Consult Documentation: Refer to SAP documentation or help resources specific to the Oil and Gas module for guidance on allocation processes and troubleshooting.
Contact Support: If the issue persists after checking the above points, consider reaching out to SAP support or your internal IT team for further assistance.
Related Information:
By following these steps, you should be able to identify and resolve the cause of the OIUPR732 error in your SAP system.
Get instant SAP help. Start your 7-day free trial now.
OIUPR730
WARNING: THE THEORETICAL RESIDUE HAS BEEN CALCULATED AS ADJUSTED PROD
What causes this issue? THE THEORETICAL RESIDUE HAS BEEN CALCULATED AS ADJUSTED PRODUCTION LESS PLANT SHRINKAGE, PLANT FLARE, PLANT, FUEL, GAS EXTRAC...
OIUPR728
WARNING: CALC PRODUCTION IS GREATER THAN ZERO. THE & IS AN INJECTION &
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIUPR733
WARNING: THE EXTRACTION LOSS FACTOR RECORD WAS NOT WRITTEN.
What causes this issue? THE CALCULATED PRODUCTION WAS CALCULATED TO BE 0 AFTER MULTIPLYING BY 1.1System Response The system issues an error message ...
OIUPR734
WARNING: THE EXTRACTION LOSS FACTOR RECORD WAS NOT WRITTEN.
What causes this issue? THE CALCULATED PRODUCTION WAS CALCULATED TO BE 0 AFTER MULTIPLYING BY THE USER ENTERED EXTRACTION LOSS FACTORSystem Response ...