Message type: E = Error
Message class: OIUPR - PRA Production Messages
Message number: 717
Message text: WARNING: A WATER CHAIN VOL HAS BEEN CALCULATED BUT NOT ALLOCATED
NO PRODUCING WELLS WERE FOUND IN THIS NETWORK
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
OIUPR717
- WARNING: A WATER CHAIN VOL HAS BEEN CALCULATED BUT NOT ALLOCATED ?The SAP error message OIUPR717, which states "WARNING: A WATER CHAIN VOL HAS BEEN CALCULATED BUT NOT ALLOCATED," typically occurs in the context of SAP's Oil and Gas or Utilities modules, particularly when dealing with water management in production or distribution processes.
Cause: This warning indicates that the system has calculated a volume of water associated with a water chain (which could be related to production, transportation, or treatment processes) but has not allocated that volume to any specific entity or process. This can happen due to several reasons, including:
Configuration Issues: The system may not be properly configured to allocate water volumes to the relevant processes or entities. Missing Data: Required data for allocation may be missing or incomplete, preventing the system from making the necessary allocations. Process Flow Issues: There may be issues in the process flow where the water volume is not being directed to the appropriate destination. User Input Errors: Incorrect or
Get instant SAP help. Sign up for our Free Essentials Plan.
OIUPR716
WARNING: CALC PROD ROW NOT INSERTED. A ROW EXISTS FOR & IN ANOTHER NTWK
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIUPR715
Multiple downstream nodes are connected to the listed node and at least
What causes this issue? one of those nodes is not a mp type 17 (allocation), 04 (deduct), 12 (theoretical), 54 (glg receipt), 57 (rlf receipt), or 5...
OIUPR718
Unable to alloc calculated water chain volume to upstream well/wc's
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIUPR719
Fuel System adj metered qy < allocating vol, so DN is out of balance
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...