Do you have any question about this error?
Message type: E = Error
Message class: OIUPR - PRA Production Messages
Message number: 717
Message text: WARNING: A WATER CHAIN VOL HAS BEEN CALCULATED BUT NOT ALLOCATED
NO PRODUCING WELLS WERE FOUND IN THIS NETWORK
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
OIUPR717
- WARNING: A WATER CHAIN VOL HAS BEEN CALCULATED BUT NOT ALLOCATED ?The SAP error message OIUPR717, which states "WARNING: A WATER CHAIN VOL HAS BEEN CALCULATED BUT NOT ALLOCATED," typically occurs in the context of SAP's Oil and Gas or Utilities modules, particularly when dealing with water management in production or distribution processes.
Cause:
This warning indicates that the system has calculated a volume of water associated with a water chain (which could be related to production, transportation, or treatment processes) but has not allocated that volume to any specific entity or process. This can happen due to several reasons, including:
- Configuration Issues: The system may not be properly configured to allocate water volumes to the relevant processes or entities.
- Missing Data: Required data for allocation may be missing or incomplete, preventing the system from making the necessary allocations.
- Process Flow Issues: There may be issues in the process flow where the water volume is not being directed to the appropriate destination.
- User Input Errors: Incorrect or incomplete user inputs during data entry or process execution can lead to this warning.
Solution:
To resolve the OIUPR717 warning, consider the following steps:
Check Configuration: Review the configuration settings related to water management in your SAP system. Ensure that all necessary parameters for allocation are correctly set up.
Review Data Entries: Verify that all relevant data entries are complete and accurate. This includes checking for any missing or incorrect information that could affect the allocation process.
Analyze Process Flow: Examine the process flow to ensure that the water volume is being directed to the correct entities or processes. Look for any bottlenecks or misconfigurations that could prevent allocation.
Consult Documentation: Refer to SAP documentation or help resources specific to your version and module for guidance on handling water chain volumes and allocations.
Run Allocation Processes: If applicable, run any allocation processes or transactions that may be necessary to allocate the calculated water volume to the appropriate entities.
Seek Support: If the issue persists, consider reaching out to your SAP support team or consulting with SAP experts who can provide more tailored assistance based on your specific system configuration and business processes.
Related Information:
By following these steps, you should be able to address the OIUPR717 warning and ensure that water volumes are properly allocated within your SAP system.
Get instant SAP help. Start your 7-day free trial now.
OIUPR716
WARNING: CALC PROD ROW NOT INSERTED. A ROW EXISTS FOR & IN ANOTHER NTWK
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIUPR715
Multiple downstream nodes are connected to the listed node and at least
What causes this issue? one of those nodes is not a mp type 17 (allocation), 04 (deduct), 12 (theoretical), 54 (glg receipt), 57 (rlf receipt), or 5...
OIUPR718
Unable to alloc calculated water chain volume to upstream well/wc's
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIUPR719
Fuel System adj metered qy < allocating vol, so DN is out of balance
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...