Do you have any question about this error?
Message type: E = Error
Message class: OIUPR - PRA Production Messages
Message number: 715
Message text: Multiple downstream nodes are connected to the listed node and at least
one of those nodes is not a mp type 17 (allocation), 04 (deduct), 12
(theoretical), 54 (glg receipt), 57 (rlf receipt), or 56 (injection
meter).
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
OIUPR715
- Multiple downstream nodes are connected to the listed node and at least ?The SAP error message OIUPR715 indicates that there is a configuration issue in the system where multiple downstream nodes are connected to a single upstream node in a process chain or data flow. This typically occurs in the context of SAP Process Integration (PI) or SAP Process Orchestration (PO) scenarios, where the data flow is not set up correctly.
Cause:
- Incorrect Configuration: The error usually arises when a node in a process chain or data flow is incorrectly configured to have multiple downstream connections, which is not allowed in certain scenarios.
- Data Flow Design: The design of the data flow may not adhere to the expected structure, leading to multiple nodes trying to connect to a single node.
- Logical Errors: There may be logical errors in the way the process is designed, leading to conflicts in the data flow.
Solution:
- Review Configuration: Check the configuration of the nodes in the process chain or data flow. Ensure that each upstream node has the correct number of downstream connections as per the design requirements.
- Adjust Connections: If multiple downstream nodes are connected to a single upstream node, consider redesigning the flow to ensure that each node connects appropriately. This may involve splitting the flow or creating additional nodes to handle the connections.
- Consult Documentation: Refer to SAP documentation or guidelines for the specific module you are working with to understand the expected configuration and limitations.
- Testing: After making adjustments, test the process to ensure that the error is resolved and that the data flow operates as intended.
Related Information:
If the issue persists after following these steps, it may be beneficial to reach out to SAP support for further assistance.
Get instant SAP help. Start your 7-day free trial now.
OIUPR714
The well/wc is indentified as a supply source, but it is not in the DN
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIUPR713
FATAL: NW WL CMPLS DID NOT HAVE ENOUGH THEOR TO COVER UNALLOCATED VOLS
What causes this issue? NETWORK WL CMPLS DID NOT HAVE ENOUGH REMAINING THEORETICAL TO COVER UNALLOCATED VOLUMESSystem Response The system issues an ...
OIUPR716
WARNING: CALC PROD ROW NOT INSERTED. A ROW EXISTS FOR & IN ANOTHER NTWK
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIUPR717
WARNING: A WATER CHAIN VOL HAS BEEN CALCULATED BUT NOT ALLOCATED
What causes this issue? NO PRODUCING WELLS WERE FOUND IN THIS NETWORKSystem Response The system issues an error message and will not allow you to c...
Click on this link to search all SAP messages.