Message type: E = Error
Message class: OIUPR - PRA Production Messages
Message number: 649
Message text: A required mp volume was not found downstream of & &
A theoretical calculation method of Metered Volume was selected for the
listed well/well completion. This instructs the allocation process to
take the volume from a downstream MP and use it as the well/well
completion's theoretical. When attempting to do this, a volume was
not found.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Ensure that the VT of the volume at the downstream MP is valid. The
oiu_pr_mv_cfg table is used to establish valid MP Types and VT's for
the Metered Volume TCM.
Error message extract from SAP system. Copyright SAP SE.
OIUPR649
- A required mp volume was not found downstream of & & ?The SAP error message OIUPR649 indicates that a required multi-product (mp) volume was not found downstream in the process. This error typically occurs in the context of SAP's Oil and Gas (O&G) module, particularly when dealing with product movements, inventory management, or logistics.
Cause:
Missing Volume: The specific multi-product volume that the system expects to find is not available in the downstream process. This could be due to various reasons such as:
- The volume has not been created or is not properly configured in the system.
- The volume has been deleted or moved.
- There is a mismatch in the product type or specifications.
Configuration Issues: There may be issues with the configuration of the multi-product volume in the system, such as incorrect settings or parameters.
Data Integrity Issues: There could be data integrity issues, such as missing or incorrect entries in the database that prevent the system from recognizing the required volume.
Solution:
Check Volume Configuration: Verify that the required multi-product volume is correctly configured in the system. Ensure that all necessary parameters and settings are in place.
Volume Availability: Check if the required volume exists in the system. If it does not, you may need to create it or restore it if it was deleted.
Data Consistency: Run data consistency checks to ensure that all relevant data entries are correct and complete. This may involve checking related tables and records in the database.
Review Process Flow: Analyze the process flow to ensure that the required volume is being referenced correctly. Make sure that the upstream processes are correctly linked to the downstream processes.
Consult Documentation: Refer to SAP documentation or help resources specific to the Oil and Gas module for additional guidance on handling this error.
Contact Support: If the issue persists after checking the above points, consider reaching out to SAP support or your internal IT team for further assistance.
Related Information:
By following these steps, you should be able to identify the cause of the OIUPR649 error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
OIUPR648
GLG is setup on the DNAP, but no WC has a producing method of "Gas Lift"
What causes this issue? A "Gas Lift Gas" volume type exists in the Delivery Network's Profile yet no well completion has a Producing M...
OIUPR647
FATAL: UNESTABLISHED DEPENDENCY OF &1 / &2 EXISTS AT WC &3
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIUPR650
Did not prorate the volume & across multiple wl/wc's
What causes this issue? A WC TCM of MV was selected for the listed wl/wc, but the downstream MP used is also connected to another wl/wc.System Respo...
OIUPR651
Successful daily allocations for each day of the month do not exist.
What causes this issue? One of the following has occured: 1). The MATNR /VT listed in the detail has the sum daily box checked on the DN Allocation P...
Click on this link to search all SAP messages.