Message type: E = Error
Message class: OIUPR - PRA Production Messages
Message number: 648
Message text: GLG is setup on the DNAP, but no WC has a producing method of "Gas Lift"
A "Gas Lift Gas" volume type exists in the Delivery Network's Profile
yet no well completion has a Producing Method of "Gas Lift".
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
OIUPR648
- GLG is setup on the DNAP, but no WC has a producing method of "Gas Lift" ?The SAP error message OIUPR648 indicates that there is a configuration issue related to the Gas Lift method in the context of a specific production setup. Here’s a breakdown of the cause, potential solutions, and related information:
Cause: Configuration Issue: The error suggests that the Gas Lift method is expected to be configured for a specific Well Completion (WC) in the system, but it is not set up correctly. This could be due to: The Gas Lift method not being assigned to any of the well completions associated with the designated DNAP (Drilling and Production). The well completions may not have the necessary attributes or settings to support Gas Lift production. Data Integrity: There may be missing or incorrect data in the master data setup for the well completions or the production methods.
Solution: Check Well Completion Configuration: Navigate to the well completion records associated with the DNAP and verify if the Gas Lift method is properly assigned. Ensure
Get instant SAP help. Sign up for our Free Essentials Plan.
OIUPR647
FATAL: UNESTABLISHED DEPENDENCY OF &1 / &2 EXISTS AT WC &3
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIUPR646
& Date is more than 12 months old
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIUPR649
A required mp volume was not found downstream of & &
What causes this issue? A theoretical calculation method of Metered Volume was selected for the listed well/well completion. This instructs the allo...
OIUPR650
Did not prorate the volume & across multiple wl/wc's
What causes this issue? A WC TCM of MV was selected for the listed wl/wc, but the downstream MP used is also connected to another wl/wc.System Respo...