Do you have any question about this error?
Message type: E = Error
Message class: OIUPR - PRA Production Messages
Message number: 224
Message text: These Measurement Points will create a circular reference within DN &.
Currently, the downstream measurement point <DS:NA.OIUPR224>&V3&</>
exists as an upstream measurement point for the entered upstream
measurement point <DS:NA.OIUPR224>&V2&</>. This circular reference
cannot occur within the same delivery network. Either this DN link is
invalid or the previously entered DN link is invalid.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
OIUPR224
- These Measurement Points will create a circular reference within DN &. ?The SAP error message OIUPR224 indicates that there is a circular reference issue with measurement points in the context of a Distribution Network (DN) in SAP IS-U (Industry Solution for Utilities). This typically occurs when the configuration of measurement points leads to a situation where one measurement point references another in a way that creates a loop, making it impossible for the system to determine the correct flow of data.
Cause:
- Measurement Point Configuration: The error usually arises from incorrect configuration of measurement points, where one measurement point is set to depend on another in a circular manner.
- Data Entry Errors: Manual entry errors during the setup of measurement points can lead to circular references.
- Hierarchy Issues: If measurement points are part of a hierarchy, the relationships may not be properly defined, leading to circular dependencies.
Solution:
Review Measurement Point Configuration:
- Check the configuration of the measurement points involved in the error. Ensure that they do not reference each other in a way that creates a loop.
- Use transaction codes like
EL31
(for measurement point maintenance) to review and adjust the settings.Correct Circular References:
- Identify the measurement points that are causing the circular reference and modify their relationships to eliminate the loop.
- Ensure that each measurement point has a clear and direct relationship without any back-references.
Data Validation:
- Validate the data entries for measurement points to ensure that they are correctly set up according to business requirements.
- Use the SAP standard tools for data validation to check for inconsistencies.
Testing:
- After making changes, test the configuration to ensure that the error is resolved and that the measurement points function correctly within the distribution network.
Consult Documentation:
- Refer to SAP documentation or help notes related to measurement point configuration in IS-U for additional guidance.
Related Information:
EL31
, EL30
, and EL20
for managing measurement points and their relationships.By following these steps, you should be able to resolve the OIUPR224 error and ensure that your measurement points are correctly configured without circular references.
Get instant SAP help. Start your 7-day free trial now.
OIUPR223
Invalid Volume Indicator & for & DN or MP type &
What causes this issue? Volume Indicator <DS:NA.OIUPR223>&V1&</> is only valid for a DN that is a <DS:NA.OIUPR223>&V2&a...
OIUPR222
Volume Indicator & is required for MP type &
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIUPR225
Volume Indicator must be & for specified Volume Type
What causes this issue? If the DN is not a Gas Plant or Chained Network, Volume Types: <DS:NA.OIUPR225>&V2&</> , <DS:NA.OIUPR2...
OIUPR226
The specified Volume Type and Volume Indicator can only be used with a &
What causes this issue? If the Volume Type is <DS:NA.OIUPR226>&V2&</> , <DS:NA.OIUPR226>&V3&</> and the Volum...
Click on this link to search all SAP messages.