Message type: E = Error
Message class: OIUPR - PRA Production Messages
Message number: 223
Message text: Invalid Volume Indicator & for & DN or MP type &
Volume Indicator <DS:NA.OIUPR223>&V1&</> is only valid for a DN that
is a <DS:NA.OIUPR223>&V2&</> or MP type <DS:NA.OIUPR223>&V3&</>
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
OIUPR223
- Invalid Volume Indicator & for & DN or MP type & ?The SAP error message OIUPR223, which states "Invalid Volume Indicator & for & DN or MP type &," typically occurs in the context of SAP's Oil and Gas (O&G) module, particularly when dealing with volume-related data for delivery notes (DN) or measurement points (MP).
Cause: Invalid Volume Indicator: The error indicates that the volume indicator being used is not valid for the specified delivery note or measurement point type. This could be due to: Incorrect configuration of volume indicators in the system. The volume indicator not being defined for the specific type of delivery note or measurement point. Data entry errors where an incorrect volume indicator is being referenced. Data Inconsistencies: There may be inconsistencies in the master data or transactional data that lead to this error. Customizations: If there are custom developments or enhancements in the system, they might not be handling volume indicators correctly.
Solution: Check Volume Indicator Configuration: Go to the configuration settings for volume indicators in
Get instant SAP help. Sign up for our Free Essentials Plan.
OIUPR222
Volume Indicator & is required for MP type &
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIUPR221
Entered volume does not equal tank gauge calculated volume.
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIUPR224
These Measurement Points will create a circular reference within DN &.
What causes this issue? Currently, the downstream measurement point <DS:NA.OIUPR224>&V3&</> exists as an upstream measurement poi...
OIUPR225
Volume Indicator must be & for specified Volume Type
What causes this issue? If the DN is not a Gas Plant or Chained Network, Volume Types: <DS:NA.OIUPR225>&V2&</> , <DS:NA.OIUPR2...
Click on this link to search all SAP messages.