Do you have any question about this error?
Message type: E = Error
Message class: OIUPR - PRA Production Messages
Message number: 006
Message text: Measurement point has invalid upstream node relationship.
Measurement point has invalid upstream node relationship for volume
indicator 7, 8, or 9. The allocation process requires a one to one
relationship between the measurement point and the upstream well
completion.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
OIUPR006
- Measurement point has invalid upstream node relationship. ?The SAP error message OIUPR006, which states "Measurement point has invalid upstream node relationship," typically occurs in the context of SAP IS-U (Industry Solution for Utilities) when dealing with measurement points and their relationships in the data model. This error indicates that there is an issue with the configuration of the measurement point's upstream node, which is essential for the proper functioning of the utility billing and measurement processes.
Cause:
- Incorrect Configuration: The measurement point may be incorrectly configured with respect to its upstream node. This could mean that the upstream node does not exist, is not active, or is not properly linked to the measurement point.
- Data Integrity Issues: There may be inconsistencies in the data, such as missing or incorrect entries in the master data for measurement points or nodes.
- Hierarchy Issues: The measurement point may be part of a hierarchy that is not correctly defined, leading to invalid relationships between nodes.
- Technical Issues: There could be technical issues in the system, such as bugs or problems with the data model.
Solution:
Check Configuration: Verify the configuration of the measurement point and its upstream node. Ensure that the upstream node is correctly defined and active.
- Go to the relevant transaction (e.g., IL01 for creating measurement points) and check the details of the measurement point.
- Ensure that the upstream node is correctly assigned and exists in the system.
Data Consistency Check: Perform a data consistency check to identify any discrepancies in the measurement point and node relationships.
- Use transaction codes like OIUPR or OIUPR01 to review and correct any inconsistencies.
Hierarchy Review: Review the hierarchy of measurement points and nodes to ensure that they are correctly structured.
- Check if the upstream node is part of the same hierarchy and is correctly linked.
Consult Documentation: Refer to SAP documentation or notes related to the specific version of SAP IS-U you are using. There may be specific guidelines or patches available for this error.
Technical Support: If the issue persists, consider reaching out to SAP support or your internal IT team for further assistance. They may need to analyze the system logs or perform deeper troubleshooting.
Related Information:
By following these steps, you should be able to identify and resolve the cause of the OIUPR006 error in your SAP system.
Get instant SAP help. Start your 7-day free trial now.
OIUPR005
& & must be in the same network as & &.
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIUPR004
Delivery network allocation profile record not found
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIUPR007
No prod volume rows found for well completion
What causes this issue? VLI = GEN from OIL/GAS/WTR prod and no wcdvl recs existSystem Response The system issues an error message and will not allow...
OIUPR008
Measurement Point does not exist
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.