Do you have any question about this error?
Stop googling SAP errors. Use our Free Essentials plan instead - no credit card needed. Start Now →
Message type: E = Error
Message class: OIUPR - PRA Production Messages
Message number: 005
Message text: & & must be in the same network as & &.
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
OIUPR005
- & & must be in the same network as & &. ?The SAP error message OIUPR005 typically indicates a network-related issue where two systems or components that need to communicate with each other are not on the same network. This error often arises in scenarios involving integration between different SAP systems or when trying to access resources that require network connectivity.
Cause:
The error message "OIUPR005 & & must be in the same network as & &." suggests that the two entities (which could be servers, clients, or services) referenced by the placeholders are not reachable due to network segmentation or configuration issues. This could be due to:
- Network Configuration: The systems may be on different subnets or VLANs that do not allow communication.
- Firewall Rules: Firewalls may be blocking traffic between the two systems.
- Routing Issues: There may be routing problems that prevent the systems from seeing each other.
- DNS Resolution: If the systems are identified by hostnames, there may be issues with DNS resolution.
Solution:
To resolve the OIUPR005 error, you can take the following steps:
Check Network Configuration:
- Ensure that both systems are on the same subnet or that there is proper routing between them.
- Verify that the IP addresses and subnet masks are correctly configured.
Firewall Settings:
- Review firewall rules to ensure that traffic is allowed between the two systems.
- If necessary, create rules to permit the required traffic.
Routing Verification:
- Use tools like
ping
ortraceroute
to check connectivity and routing paths between the systems.- Ensure that there are no misconfigurations in the routing tables.
DNS Configuration:
- If using hostnames, verify that DNS is correctly resolving the names to the appropriate IP addresses.
- You can test this by using the
nslookup
ordig
command.Network Logs:
- Check network logs for any blocked connections or errors that might provide more insight into the issue.
Consult Documentation:
- Review SAP documentation or support notes related to the specific systems you are working with for any additional configuration requirements.
Related Information:
By following these steps, you should be able to identify and resolve the underlying cause of the OIUPR005 error message.
Get instant SAP help. Sign up for our Free Essentials Plan.
OIUPR004
Delivery network allocation profile record not found
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIUPR003
Delivery network does not exist
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIUPR006
Measurement point has invalid upstream node relationship.
What causes this issue? Measurement point has invalid upstream node relationship for volume indicator 7, 8, or 9. The allocation process requires a ...
OIUPR007
No prod volume rows found for well completion
What causes this issue? VLI = GEN from OIL/GAS/WTR prod and no wcdvl recs existSystem Response The system issues an error message and will not allow...
Click on this link to search all SAP messages.