Do you have any question about this error?
Stop googling SAP errors. Use our Free Essentials plan instead - no credit card needed. Start Now →
Message type: E = Error
Message class: OIUME - Measurement messages
Message number: 116
Message text: There are no readings to be checked.
The measurement application is asked to check readings but no readings
have been entered.
No check is performed.
Enter one or more readings.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
OIUME116
- There are no readings to be checked. ?The SAP error message OIUME116, which states "There are no readings to be checked," typically occurs in the context of the SAP IS-U (Industry Solution for Utilities) module, particularly when dealing with meter readings and their processing.
Cause:
This error message usually indicates that the system is unable to find any meter readings that meet the criteria for the operation you are trying to perform. This could be due to several reasons:
- No Meter Readings Recorded: There may not be any meter readings recorded for the specific period or for the specific device you are trying to check.
- Incorrect Selection Criteria: The selection criteria you are using to retrieve the readings may be too restrictive or incorrect, leading to no results being found.
- Data Not Yet Processed: If the meter readings have been entered but not yet processed or saved, they may not be available for checking.
- Technical Issues: There could be technical issues or inconsistencies in the database that prevent the readings from being displayed.
Solution:
To resolve the OIUME116 error, you can take the following steps:
Check Meter Readings: Verify that there are indeed meter readings recorded for the relevant period and device. You can do this by navigating to the appropriate transaction (e.g., transaction code EL31 for displaying meter readings).
Review Selection Criteria: Ensure that the selection criteria you are using to check the readings are correct. Adjust the date range, device number, or other parameters as necessary.
Process Pending Readings: If there are meter readings that have been entered but not processed, ensure that they are saved and processed correctly. You may need to run the relevant background jobs or processes to update the system.
Check for Technical Issues: If you suspect a technical issue, consult with your SAP Basis team to check for any database inconsistencies or errors in the system logs.
Consult Documentation: Refer to SAP documentation or help resources for additional guidance on handling meter readings and troubleshooting related issues.
Contact Support: If the issue persists after checking the above points, consider reaching out to SAP support for further assistance.
Related Information:
By following these steps, you should be able to identify the cause of the OIUME116 error and take appropriate action to resolve it.
Get instant SAP help. Sign up for our Free Essentials Plan.
OIUME115
Error found in measurement document
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIUME114
Gauge readings is required if any is entered.
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIUME117
There are no measurements to be calculated.
What causes this issue? The measurement system is asked to calculate readings for a measurement but there are no measurements active within the syste...
OIUME118
Error encountered during document send.
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.