Do you have any question about this error?
Message type: E = Error
Message class: OIUBL - PRA Balancing Messages
Message number: 122
Message text: .&: wells/MPs attached to PBA & are from more than one DOI
The system has issued a customizable message to notify that the Well
Completions / Measurement Points attached to the PBA are not all from
the same DOI.
Depending on how this error is customized, the message may trigger an
error, warning, or just informational message. If this is an error,
the report will not run until the error is fixed. If the message is
any other type (warning, informational, etc), then the report will
finish and output succussfully.
(1) To detach a Well Completion / Measurement Point from a PBA, go into
the Balancing Workplace transaction, O3UBL01_WORKPLACE, into "Master
Data" tab, into "PBA to WC/MP Xref" tab and delete the WC or MP off of
the PBA to WC/MP Cross reference.
(2) To turn off this customizable message, go into the following IMG
menu path:
,,Industry Solution Oil & Gas (PRA)
,,Global Settings
,,Customize Message Control
Enter "OIUBL" in the Application Area Box.
Press Execute
If message 122 is not in the list, press "New Entries".
Enter "122" as the Message Number.
Set the Type to "W", "E", "S", "I" or "-" for both Online and Batch
processes.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
OIUBL122
- .&: wells/MPs attached to PBA & are from more than one DOI ?The SAP error message OIUBL122 indicates that there is an issue with wells or measurement points (MPs) that are attached to a Production Business Area (PBA) and are associated with more than one Department of Interior (DOI). This typically occurs in the context of oil and gas production accounting within SAP's Oil and Gas module.
Cause:
The error arises when the system detects that the wells or measurement points linked to a specific PBA are associated with multiple DOI entities. This can happen due to:
- Data Entry Errors: Incorrect assignment of wells or MPs to different DOIs during data entry.
- Configuration Issues: Misconfiguration in the master data setup for wells, MPs, or PBAs.
- Business Logic Violations: The business rules in your organization may dictate that a PBA should only be associated with a single DOI.
Solution:
To resolve the OIUBL122 error, you can take the following steps:
Review Well and MP Assignments:
- Check the assignment of wells and MPs to the PBA in question.
- Ensure that each well or MP is only associated with one DOI.
Correct Data Entries:
- If you find that a well or MP is incorrectly assigned to multiple DOIs, correct the assignment in the master data.
- This may involve updating the DOI field for the wells or MPs in the SAP system.
Consult Configuration Settings:
- Review the configuration settings for the PBA and ensure that it is set up correctly to handle the associated wells and MPs.
- If necessary, consult with your SAP configuration team to ensure that the business rules are correctly implemented.
Run Consistency Checks:
- Use SAP tools to run consistency checks on your master data to identify any discrepancies or issues that may lead to this error.
Documentation and Training:
- Ensure that users entering data are trained on the importance of correct DOI assignments and the implications of incorrect data entry.
Related Information:
By following these steps, you should be able to identify and resolve the cause of the OIUBL122 error in your SAP system.
Get instant SAP help. Start your 7-day free trial now.
OIUBL121
Delivery network & has open PPN for Prd Dt &. PBA &.
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIUBL120
Current PBA & report contains catch-up month &
What causes this issue? This is a message saying that a Balancing Statement was not generated for the indicted month; therefore, it will be rolled in...
OIUBL123
PBA & contains well/measurement point from DOI &
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIUBL124
.&: & of DOI & not attached to PBA &
What causes this issue? The system has issued a customizable message to notify that not all of the Well Completions/Measurement Points within the DOI...
Click on this link to search all SAP messages.