Do you have any question about this error?
Message type: E = Error
Message class: OIJ_EL - OIL TSW: Messages for TSW Execution Layer
Message number: 723
Message text: Opening reading (&1) different from last closing reading (&2)
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
OIJ_EL723
- Opening reading (&1) different from last closing reading (&2) ?The SAP error message OIJ_EL723 indicates a discrepancy between the opening reading and the last closing reading for a specific measurement point or equipment. This error typically occurs in the context of the SAP Oil and Gas (OIJ) module, particularly when dealing with measurement documents or readings for tanks, meters, or other equipment.
Cause:
- Data Entry Error: The opening reading entered may be incorrect or not updated properly, leading to a mismatch with the last recorded closing reading.
- Missing Closing Reading: If a closing reading was not recorded before entering a new opening reading, this can lead to discrepancies.
- Incorrect Sequence of Operations: The readings may not have been entered in the correct sequence, or there may have been an attempt to enter a new reading without properly closing the previous one.
- System Configuration Issues: There may be configuration issues in the SAP system that affect how readings are processed and validated.
Solution:
- Verify Readings: Check the opening and closing readings in the system. Ensure that the opening reading is indeed greater than or equal to the last closing reading.
- Correct Data Entry: If there is an error in the readings, correct the opening reading to match the last closing reading or enter the correct closing reading if it was missed.
- Review Measurement Documents: Look at the measurement documents to ensure that all readings have been recorded correctly and in the right order.
- Consult Documentation: Refer to SAP documentation or help resources for specific instructions on handling measurement readings in the OIJ module.
- System Configuration Check: If the issue persists, consult with your SAP Basis or technical team to check for any configuration issues that may be causing the error.
Related Information:
By following these steps, you should be able to resolve the OIJ_EL723 error and ensure that your measurement readings are accurate and properly recorded in the SAP system.
Get instant SAP help. Start your 7-day free trial now.
OIJ_EL722
Meter reading date or time can not be blank
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIJ_EL721
Invalid dip entered
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIJ_EL724
Stop meter reading crosses over the zero mark
What causes this issue? The quantity to be transferred will result in a stop meter reading which is greater than the maximum meter reading. As a resu...
OIJ_EL725
Ticket could not be Actualized.Check the Error Log.
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.