Do you have any question about this error?
Message type: E = Error
Message class: O3 - IS-Oil: HPM messages (goods movements, QCI, deliveries)
Message number: 278
Message text: AGA8:Error code 11: Method was not 1 or 2
The method specifies which gross method is used for the calculation of
the compression factor. "1" or "2" are valid entries.
The QCI (Quantity Conversion Interface) stops processing.
Within customizing, check if the conversion group has set the correct
flag for the c-code call: <DS:TRAN.O588>Display conversion group
settings</>: Gas conversion handling indicator has to be set to 1 or 2.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
O3278
- AGA8:Error code 11: Method was not 1 or 2 ?The SAP error message O3278 AGA8: "Error code 11: Method was not 1 or 2" typically occurs in the context of the SAP Advanced Business Application Programming (ABAP) or when dealing with specific functionalities in SAP modules, such as Asset Accounting (FI-AA) or other areas where methods are defined for processing.
Cause:
The error message indicates that a method being called or referenced in the program does not match the expected values. Specifically, it suggests that the method should be either 1 or 2, but the value being passed is different. This could be due to:
- Incorrect Configuration: The method being referenced may not be properly configured in the system.
- Data Entry Error: The input data or parameters being passed to the method may be incorrect or invalid.
- Custom Code Issues: If there are custom developments or enhancements, there may be a bug or logic error in the code that is causing the wrong method to be called.
- Version Mismatch: If there are different versions of the software or components, it may lead to incompatibility issues.
Solution:
To resolve the error, you can take the following steps:
Check Configuration: Review the configuration settings related to the method in question. Ensure that the methods are correctly defined and that the expected values (1 or 2) are set up properly.
Validate Input Data: Ensure that the data being passed to the method is valid. Check for any data entry errors or inconsistencies.
Review Custom Code: If there are any custom developments, review the code to ensure that the correct method is being called. Look for any hardcoded values or logic that may lead to an incorrect method being referenced.
Debugging: Use the SAP debugger to trace the execution of the program and identify where the error is occurring. This can help pinpoint the exact location and cause of the issue.
Consult Documentation: Refer to SAP documentation or notes related to the specific module or functionality you are working with. There may be known issues or additional guidance available.
SAP Support: If the issue persists and you cannot find a resolution, consider reaching out to SAP support for assistance. Provide them with the error message details and any relevant context to help them diagnose the issue.
Related Information:
By following these steps, you should be able to identify the cause of the error and implement a solution.
Get instant SAP help. Start your 7-day free trial now.
O3277
AGA8:Error code 9: Invalid term in routine VIRGS
What causes this issue? The AGA c-code routines cannot calculate a compression factor.System Response The QCI (Quantity Conversion Interface) stops ...
O3276
AGA8:Error code 8: Combined values of input parameters are inconsistent
What causes this issue? The combined value of the relative test density, the heating value and the carbon dioxide content is not consistent.System Re...
O3279
AGA8:Error code 13: Flowing temperature (mat. temperature)is out of range
What causes this issue? The flowing temperature is not within the valid range for the AGA c-code.System Response The QCI (Quantity Conversion Interf...
O3280
AGA8:Error code 12: Flowing pressure (material pressure) is out of range
What causes this issue? The flowing pressure is not within the valid range for the AGA c-code.System Response The QCI (Quantity Conversion Interface...
Click on this link to search all SAP messages.