Message type: E = Error
Message class: O3 - IS-Oil: HPM messages (goods movements, QCI, deliveries)
Message number: 274
Message text: AGA8:Error code 6: No convergence in routine DGROSS
The AGA c-code routines cannot calculate a compression factor.
The QCI (Quantity Conversion Interface) stops processing.
Check the input parameters for the AGA c-code routines.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
O3274
- AGA8:Error code 6: No convergence in routine DGROSS ?The SAP error message O3274 AGA8: "Error code 6: No convergence in routine DGROSS" typically occurs in the context of the SAP system's calculation routines, particularly in the area of asset accounting or depreciation calculations. This error indicates that the system was unable to converge on a solution during a calculation process, which can happen for various reasons. Causes: Data Issues: There may be inconsistencies or errors in the master data or transaction data related to the asset. This could include incorrect values, missing data, or invalid configurations. Configuration Problems: The configuration settings for asset accounting may not be set up correctly, leading to issues during the calculation process. Complex Calculations: The calculation routine may be too complex or may involve too many variables, leading to convergence issues. System Performance: If the system is under heavy load or if there are performance issues, it may affect the ability of the calculation routine to converge. Solutions: Check Data
Get instant SAP help. Sign up for our Free Essentials Plan.
O3273
AGA8:Error code 5: The root was not bounded in routine DGROSS
What causes this issue? The AGA c-code routines can not calculate a compression factor.System Response The QCI (Quantity Conversion Interface) stops...
O3272
Test density is calculated by the AGA c-code routines
What causes this issue? The Quantity Calculation Interface (QCI) contains built-in routines that are used to determine the base density, if a test de...
O3275
AGA8:Error code 7: Square root in routine VIRGS is negative
What causes this issue? The AGA c-code routines cannot calculate a compression factor.System Response The QCI (Quantity Conversion Interface) stops ...
O3276
AGA8:Error code 8: Combined values of input parameters are inconsistent
What causes this issue? The combined value of the relative test density, the heating value and the carbon dioxide content is not consistent.System Re...