Do you have any question about this error?
Message type: E = Error
Message class: O3 - IS-Oil: HPM messages (goods movements, QCI, deliveries)
Message number: 272
Message text: Test density is calculated by the AGA c-code routines
The Quantity Calculation Interface (QCI) contains built-in routines that
are used to determine the base density, if a test density and test
conditions are entered. Customers can modify those calculations using
Business Add-In methods. If the AGA c-code routines are active, and the
density type is set to "relative density (air) = 4" in the conversion
group, the test density entered in the QCI will be overwritten with the
value calculated by the AGA routines.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
This message can be customized to appear as an information, warning or
error message, or not to appear at all (Transaction O591).
Error message extract from SAP system. Copyright SAP SE.
O3272
- Test density is calculated by the AGA c-code routines ?The SAP error message O3272, which states "Test density is calculated by the AGA c-code routines," typically relates to issues in the calculation of density for gas measurement in the context of SAP's process management or measurement systems. This error is often encountered in industries dealing with gas measurement, such as oil and gas, where accurate density calculations are crucial for billing and reporting.
Cause:
- Configuration Issues: The error may arise from incorrect configuration settings in the SAP system related to the AGA (American Gas Association) routines used for density calculations.
- Missing or Incorrect Data: If the input data required for the AGA routines is missing or incorrect, it can lead to this error. This includes parameters like temperature, pressure, and gas composition.
- Software Bugs: There may be bugs or issues in the version of the SAP software being used that affect the execution of the AGA routines.
- Incompatibility: The routines may not be compatible with the specific version of SAP or the configuration of the system.
Solution:
- Check Configuration: Review the configuration settings related to gas measurement and ensure that they are set up correctly according to the AGA standards.
- Validate Input Data: Ensure that all necessary input data for the density calculation is present and accurate. This includes checking the temperature, pressure, and gas composition data.
- Update Software: If the issue is due to a bug, check for any available updates or patches for your SAP system that may resolve the issue.
- Consult Documentation: Refer to the SAP documentation or help resources for specific guidance on the AGA routines and how to troubleshoot related errors.
- Contact SAP Support: If the issue persists, consider reaching out to SAP support for assistance. They can provide more detailed insights and help resolve the issue.
Related Information:
By following these steps, you should be able to identify the cause of the O3272 error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
O3271
Density type has to be set to 4 for the chosen AGA conversion
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
O3270
API c-codes require correct temperature unit
What causes this issue? You have chosen a type of conversion handling for liquid petroleum products, in which the API (American Petroleum Institute)...
O3273
AGA8:Error code 5: The root was not bounded in routine DGROSS
What causes this issue? The AGA c-code routines can not calculate a compression factor.System Response The QCI (Quantity Conversion Interface) stops...
O3274
AGA8:Error code 6: No convergence in routine DGROSS
What causes this issue? The AGA c-code routines cannot calculate a compression factor.System Response The QCI (Quantity Conversion Interface) stops ...