Do you have any question about this error?
Message type: E = Error
Message class: O3 - IS-Oil: HPM messages (goods movements, QCI, deliveries)
Message number: 214
Message text: QCI: Unit of parameter & is missing.
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
O3214
- QCI: Unit of parameter & is missing. ?The SAP error message O3214, which states "QCI: Unit of parameter & is missing," typically occurs in the context of Quality Management (QM) within SAP. This error indicates that a required unit of measure for a specific parameter in a quality inspection characteristic is not defined or is missing.
Cause:
- Missing Unit of Measure: The most common cause is that the unit of measure for a quality characteristic has not been defined in the system.
- Configuration Issues: There may be issues in the configuration of the quality inspection characteristics or the material master data.
- Data Inconsistencies: The data related to the inspection plan or the material may be inconsistent or incomplete.
Solution:
To resolve the O3214 error, you can follow these steps:
Check Inspection Characteristics:
- Go to the inspection plan associated with the material and check the characteristics defined.
- Ensure that each characteristic has a unit of measure assigned.
Define Unit of Measure:
- If a unit of measure is missing, you can define it in the inspection characteristic settings.
- Navigate to the transaction code
QCC1
(Create Inspection Characteristic) orQCC2
(Change Inspection Characteristic) and ensure that the unit of measure is specified.Material Master Data:
- Check the material master data for the relevant material using transaction code
MM03
.- Ensure that the unit of measure is correctly defined in the basic data and sales views.
Review Configuration:
- If you have access, review the configuration settings for Quality Management in the SAP system to ensure that all necessary settings are correctly configured.
Consult Documentation:
- Refer to SAP documentation or help resources for additional guidance on setting up quality inspection characteristics and units of measure.
Testing:
- After making the necessary changes, test the process again to ensure that the error is resolved.
Related Information:
QCC1
, QCC2
, QCP1
, and MM03
for managing inspection characteristics and material data.If the problem persists after following these steps, it may be beneficial to consult with your SAP support team or a functional consultant specializing in Quality Management.
Get instant SAP help. Start your 7-day free trial now.
O3213
QCI: Parameter & not defined in table OIB07
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
O3212
Tables T006 and T006_OIB do not match
What causes this issue? For Oil & Gas-specific unit of measure definitions, the IS-OIL solution contains, starting with release 4.6B, table T006_...
O3215
QCI: Parameter & not found in internal table
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
O3216
QCI: Structure & does not exist - internal processing error
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.