Do you have any question about this error?
Message type: E = Error
Message class: O3 - IS-Oil: HPM messages (goods movements, QCI, deliveries)
Message number: 117
Message text: Parameter &1 doesn't exist in the reading group &2.
The parameter does not exist in the reading group. The reading group was
changed.
Only displaying the parameter name and parameter description is
possible.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
O3117
- Parameter &1 doesn't exist in the reading group &2. ?The SAP error message O3117, which states "Parameter &1 doesn't exist in the reading group &2," typically occurs in the context of SAP's IS-U (Industry Solution for Utilities) module, particularly when dealing with master data or configuration settings related to reading groups for meter readings.
Cause:
This error usually arises due to one of the following reasons:
Missing Parameter: The parameter specified in the error message (represented by &1) is not defined in the reading group (represented by &2). This could happen if the parameter was deleted or never created.
Incorrect Configuration: There may be a misconfiguration in the reading group settings, where the system is trying to access a parameter that is not valid for the specified reading group.
Data Inconsistency: There could be inconsistencies in the master data or configuration tables that lead to the system being unable to find the specified parameter.
Solution:
To resolve the error, you can take the following steps:
Check Reading Group Configuration:
- Go to the configuration settings for the reading group in transaction code
SPRO
.- Navigate to the relevant section for meter reading and check if the parameter exists in the specified reading group.
Create or Modify Parameter:
- If the parameter does not exist, you may need to create it. Ensure that it is correctly defined and associated with the appropriate reading group.
- If the parameter exists but is incorrectly configured, modify it to ensure it aligns with the requirements of the reading group.
Review Master Data:
- Check the master data related to the meter readings and ensure that all necessary parameters are correctly defined and linked to the reading group.
Consult Documentation:
- Refer to SAP documentation or help resources for specific details on the reading group and parameters to ensure compliance with best practices.
Testing:
- After making changes, perform tests to ensure that the error no longer occurs and that the system behaves as expected.
Related Information:
SPRO
for configuration, EL31
for meter reading, and EL30
for reading group maintenance.By following these steps, you should be able to identify the root cause of the error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
O3116
No plant found
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
O3115
No materials selected
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
MN272
Busn. vol. update for reb. arrang. &1 not possible (final sett. effected)
What causes this issue? Translation: in part identical to NAA040/NAA401 Settlement accounting has already been effected for rebate arrangement &V...
MN273
Function & canceled for condition record
What causes this issue? During execution of function &V1&, more than &V2& messages were issued.System Response Since too many error ...
Click on this link to search all SAP messages.