Message type: E = Error
Message class: O3 - IS-Oil: HPM messages (goods movements, QCI, deliveries)
Message number: 095
Message text: Dimension "heating value (volume)" is missing in Table T006D
There is no "heating value (volume)" dimension defined in Table T006D.
The Quantity Conversion Interface (QCI) stops processing.
Maintain the "heating value" dimension in Table T006D (Transaction
CUNI). Use the entries delivered with IS OIL template client 065 as a
blueprint for this activity.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
O3095
- Dimension "heating value (volume)" is missing in Table T006D ?The SAP error message O3095 indicates that there is a missing dimension, specifically "heating value (volume)," in the table T006D. This table is used in SAP to store unit of measure (UoM) information, including dimensions related to various measurement units.
Cause: The error typically arises due to one of the following reasons: Missing Configuration: The dimension for "heating value (volume)" has not been defined in the T006D table. This can happen if the necessary configuration for handling this specific measurement unit has not been completed. Data Inconsistency: There may be inconsistencies in the data or configuration settings that prevent the system from recognizing the required dimension. Custom Development: If there are custom developments or enhancements in the system that reference this dimension, and it is not properly configured, it can lead to this error.
Solution: To resolve the error, you can follow these steps: Check Table T006D: Use transaction code SE11 (Data Dictionary) to view the T006D table. Check if
Get instant SAP help. Sign up for our Free Essentials Plan.
O3094
Dimension "pressure" is missing in Table T006D
What causes this issue? There is no "pressure" dimension defined in table T006D.System Response The Quantity Conversion Interface (QCI) st...
O3093
Attention: Documents have been archived ! Results may be incorrect !
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
O3096
Dimension "density" is missing in Table T006D
What causes this issue? There is no "density" dimension defined in Table T006D.System Response The Quantity Conversion Interface (QCI) sto...
O3097
SI unit for dimension "energy" not found in Table T006
What causes this issue? There is no SI unit for the "energy" dimension defined in Table T006.System Response The Quantity Conversion Inter...
Click on this link to search all SAP messages.