Do you have any question about this error?
Message type: E = Error
Message class: KE -
Message number: 246
Message text: Derivation structure & has not been activated
You cannot define a derivation rule because the derivation structure is
not activated until it has been saved.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
If you want to define a derivation rule, you must first activate the
appropriate derivation structure. You can perform this using program
RKEABL00. Note that this report activates all derivation structures
which have been defined but not yet activated.
Error message extract from SAP system. Copyright SAP SE.
KE246
- Derivation structure & has not been activated ?The SAP error message KE246, which states "Derivation structure & has not been activated," typically occurs in the context of Profitability Analysis (CO-PA) when a derivation structure has not been properly activated in the system. This can prevent the system from deriving values as expected during the execution of certain transactions or reports.
Cause:
- Inactive Derivation Structure: The derivation structure referenced in the error message has not been activated in the system. This can happen if the structure was created but not yet activated.
- Configuration Issues: There may be issues in the configuration settings related to the derivation structure or the associated characteristics.
- Transport Issues: If the derivation structure was transported from another system, it may not have been activated in the target system.
Solution:
Activate the Derivation Structure:
- Go to the transaction code KE4S (for activating derivation structures).
- Enter the derivation structure name that is mentioned in the error message.
- Activate the structure by following the prompts.
Check Configuration:
- Ensure that all necessary settings related to the derivation structure are correctly configured.
- Review the characteristics and value fields associated with the derivation structure to ensure they are set up properly.
Transport Management:
- If the derivation structure was transported, check the transport logs to ensure that the transport was successful and that all necessary objects were included.
- If needed, re-transport the derivation structure and activate it in the target system.
Testing:
- After activation, perform a test to ensure that the derivation structure is functioning as expected and that the error message no longer appears.
Related Information:
Transaction Codes:
Documentation: Refer to SAP Help documentation for detailed information on configuring and managing derivation structures in CO-PA.
SAP Notes: Check for any relevant SAP Notes that may address specific issues or bugs related to the derivation structure.
Support: If the issue persists after following the above steps, consider reaching out to your SAP support team or consulting with an SAP expert for further assistance.
By following these steps, you should be able to resolve the KE246 error and ensure that your derivation structures are properly activated and functioning.
Get instant SAP help. Start your 7-day free trial now.
KE245
Entering & is not allowed
What causes this issue? Entry &V1& is not contained in check table &V2&.System Response The system issues an error message and will ...
KE244
Limit the number of target fields
What causes this issue? When defining derivation structure &V1&, the system generates an entry screen for maintaining the derivation rules. A...
KE247
Derivation rule & has been split
What causes this issue? The interval &V2 to &V3& for derivation rule &V1& was split. The system issues an error message and will ...
KE248
Derivation rule has not been split
What causes this issue? Derivation rule &V1& was not split because no data was changed in the divided interval.System Response The system is...
Click on this link to search all SAP messages.