Message type: E = Error
Message class: KE -
Message number: 107
Message text: Only one type of profitability analysis was activated
Operating concern &V1& is set up for both forms of Profitability
Analysis (costing-based and account-based).
You have set an active indicator for only one form. Note that no data
will be transferred to the form of Profitability Analysis that you did
not activate. If this form is activated at a later point, the data
posted up to that point will be missing.
Error message extract from SAP system. Copyright SAP SE.
KE107
- Only one type of profitability analysis was activated ?The SAP error message KE107 ("Only one type of profitability analysis was activated") typically occurs in the context of Profitability Analysis (CO-PA) when there is an attempt to use multiple types of profitability analysis simultaneously, which is not allowed in SAP.
Cause: This error arises when: You have not activated the required type of profitability analysis (either account-based or costing-based). You are trying to perform operations that require a different type of profitability analysis than what is currently activated in your system. There may be a configuration issue where the system is set up to use one type of analysis, but the transaction or report you are trying to execute is expecting another.
Solution: To resolve the KE107 error, you can follow these steps: Check Current Configuration: Go to the configuration settings in SAP for Profitability Analysis (Transaction code: SPRO). Navigate to Controlling > Profitability Analysis > Basic Settings > Activate Profitability Analysis. Verify which type of profitability analysis is currently
Get instant SAP help. Sign up for our Free Essentials Plan.
KE106
Operating concern & only allows the activity flag &
What causes this issue? Operating concern &V1& has only been generated for one form of Profitability Analysis (costing-based or account-based...
KE105
Do not use special characters when entering operating concern
What causes this issue? The operating concern &V1& is not allowed. The name of an operating concern can only contain letters, numbers and und...
KE108
Active flag was changed
<ZH>Note that when you change this active indicator, some data will no longer be transferred to Profitability Analysis.</> The active ind...
KE109
Value "&1" is not allowed for characteristic "&2"
What causes this issue? The system tried to create a line item in operating concern &V4& with the value &V1& for the characteristic &...
Click on this link to search all SAP messages.