Message type: E = Error
Message class: ITOBFLTCON - Messages for Consumption Control
Message number: 040
Message text: Area allowed for the primary counter is &1 &3 to &2 &3
The counter reading of the primary counter that you entered lies
outside of the tolerance area that you defined in Customizing.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Enter a counter reading between &V1& &V3& and &V2& &V3&.
Error message extract from SAP system. Copyright SAP SE.
ITOBFLTCON040
- Area allowed for the primary counter is &1 &3 to &2 &3 ?The SAP error message ITOBFLTCON040 typically occurs in the context of the SAP system when dealing with the configuration of counters, particularly in the area of maintenance or logistics. This error indicates that the area allowed for the primary counter is not correctly defined or is being violated.
Cause: The error message "Area allowed for the primary counter is &1 &3 to &2 &3" suggests that the system is trying to access or process a counter value that falls outside the defined range for that counter. The placeholders (&1, &2, &3) represent specific values related to the counter's configuration, such as the minimum and maximum values allowed. Possible Causes: Incorrect Configuration: The primary counter may not be configured correctly in the system, leading to an invalid range. Data Entry Error: The user may have entered a counter value that exceeds the defined limits. Master Data Issues: The master data related to the counter may be incomplete
Get instant SAP help. Sign up for our Free Essentials Plan.
ITOBFLTCON032
You have not recorded a primary consumption
What causes this issue? You have not yet specified any consumed amount for the primary fuel counter.System Response The system issues an error messa...
ITOBFLTCON031
Counter reading must be greater than in last document
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
ITOBFLTCON041
The primary counter reading must be greater than &1 &2
What causes this issue? The counter reading of the primary counter that you entered lies outside the tolerance area that you defined in Customizing....
ITOBFLTCON042
The primary counter reading must be less than &1 &2
What causes this issue? The counter reading of the primary counter that you entered lies outside of the tolerance area that you defined in Customizi...
Click on this link to search all SAP messages.