Do you have any question about this error?
Message type: E = Error
Message class: /ISDFPS/PM_DIS -
Message number: 501
Message text: Measuring point &1 can only be distributed with its technical object
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
/ISDFPS/PM_DIS501
- Measuring point &1 can only be distributed with its technical object ?The SAP error message
/ISDFPS/PM_DIS501 Measuring point &1 can only be distributed with its technical object
typically occurs in the context of the SAP Plant Maintenance (PM) module, particularly when dealing with measuring points and their associated technical objects (like equipment or functional locations).Cause:
This error message indicates that the system is trying to distribute a measuring point (MP) without its associated technical object. In SAP, measuring points are linked to technical objects, and they cannot be processed or distributed independently. The error usually arises in scenarios such as:
- Missing Technical Object: The measuring point is not linked to a technical object, or the technical object is not included in the distribution.
- Incorrect Distribution Settings: The distribution settings may not be configured correctly, leading to the inability to distribute the measuring point without its technical object.
- Data Inconsistency: There may be inconsistencies in the data related to the measuring point or its technical object.
Solution:
To resolve this error, you can take the following steps:
Check the Measuring Point Configuration:
- Go to the measuring point in question and verify that it is correctly linked to a technical object (equipment or functional location).
- Ensure that the technical object is active and properly configured.
Review Distribution Settings:
- Check the distribution settings in the relevant configuration (transaction codes like
SPRO
for configuration).- Ensure that the settings allow for the distribution of measuring points along with their technical objects.
Re-Distribute the Measuring Point:
- If the measuring point was previously distributed, try to re-distribute it along with its technical object.
- Use the appropriate transaction (like
IW38
for work orders orIK17
for measuring points) to initiate the distribution process.Check for Data Inconsistencies:
- Use transaction codes like
SE16N
to check the relevant tables (e.g.,IMPT
for measuring points) for any inconsistencies or missing links.- If inconsistencies are found, correct them in the database.
Consult Documentation:
- Refer to SAP documentation or help resources for more detailed information on measuring points and their distribution.
Contact SAP Support:
- If the issue persists after trying the above steps, consider reaching out to SAP support for further assistance.
Related Information:
IK01
(Create Measuring Point), IK02
(Change Measuring Point), and IK03
(Display Measuring Point).By following these steps, you should be able to identify the root cause of the error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
/ISDFPS/PM_DIS500
Program error: Object type &1 is not admissible
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/ISDFPS/PM_DIS405
You require authorization for transaction &1
What causes this issue? Before you can start the program &V2&, you need authorization for &V1&.System Response The program cannot be...
/ISDFPS/PM_DIS502
Maintenance item &1 can only be distributed with maintenance plan &2
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/ISDFPS/PM_DIS800
*** Text for STEP IDs ***
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.