Do you have any question about this error?
Message type: E = Error
Message class: IR - PM: IMRC - Measurement Readings and Counters
Message number: 184
Message text: Reference MeasPoint does not come from the construction type allocated
The current <DS:GLOS.measuring_point>measuring point</> or the
measuring point to be created belongs to a piece of equipment or
functional location. You are trying to allocate the measuring point a
reference measuring point that does not belong to the
<DS:GLOS.construction_type>construction type</> currently assigned to
the piece of equipment or functional location.
The assignment is not allowed.
Choose a reference measuring point of the construction type that is
currently assigned, or create the required reference measuring point
for the construction type assigned.
Error message extract from SAP system. Copyright SAP SE.
IR184
- Reference MeasPoint does not come from the construction type allocated ?The SAP error message IR184, which states "Reference MeasPoint does not come from the construction type allocated," typically occurs in the context of SAP's Industry Solution for Utilities (IS-U) when dealing with measurement points and their associated construction types.
Cause:
This error usually arises when there is a mismatch between the measurement point you are trying to use and the construction type that has been allocated to it. Specifically, it indicates that the reference measurement point you are trying to access or manipulate does not belong to the expected construction type. This can happen due to:
- Incorrect Configuration: The measurement point may not be correctly configured in relation to the construction type.
- Data Inconsistency: There may be inconsistencies in the master data for measurement points and construction types.
- Wrong Reference Point: The reference measurement point being used may not be valid for the operation you are trying to perform.
Solution:
To resolve this error, you can take the following steps:
Check Measurement Point Configuration:
- Go to the transaction code
ES32
(or the relevant transaction for your version) to check the configuration of the measurement point.- Ensure that the measurement point is correctly assigned to the appropriate construction type.
Verify Construction Type:
- Use transaction code
ES01
to check the details of the construction type.- Ensure that the construction type is correctly defined and that it includes the measurement point you are trying to use.
Review Master Data:
- Check the master data for both the measurement point and the construction type to ensure there are no discrepancies.
- You can use transaction codes like
ES03
for measurement points andES02
for construction types to review their details.Correct Reference Measurement Point:
- If you are using a reference measurement point in your operation, ensure that it is valid and correctly linked to the construction type you are working with.
Consult Documentation:
- Review SAP documentation or help files related to measurement points and construction types for additional guidance.
Contact Support:
- If the issue persists after checking the above points, consider reaching out to your SAP support team or consulting with an SAP expert who specializes in IS-U.
Related Information:
ES01
, ES02
, ES03
, and ES32
for managing measurement points and construction types.By following these steps, you should be able to identify the root cause of the error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
IR183
Equipment MeasPoints can only refer to construction type RefMeasPoints
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
IR182
Data was copied from the new reference measuring point
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
IR185
The reference MeasPoint does not come from the RefLocation assigned
What causes this issue? The current <DS:GLOS.measuring_point>measuring point</> or the measuring point to be created belongs to a functio...
IR186
RefMeasPoint has a different dimension -> assignment not possible
What causes this issue? You are trying to assign the current <DS:GLOS.measuring_point>measuring point</> a different reference measuring ...
Click on this link to search all SAP messages.