Message type: E = Error
Message class: IR - PM: IMRC - Measurement Readings and Counters
Message number: 185
Message text: The reference MeasPoint does not come from the RefLocation assigned
The current <DS:GLOS.measuring_point>measuring point</> or the
measuring point to be created belongs to a functional location. You are
trying to allocate the measuring point a reference measuring point that
does not belong to the reference functional location.
The assignment is not allowed.
Choose a reference measuring point of the reference location that is
currently assigned, or create the required reference measuring point
for the reference location assigned.
Error message extract from SAP system. Copyright SAP SE.
IR185
- The reference MeasPoint does not come from the RefLocation assigned ?The SAP error message IR185, which states "The reference MeasPoint does not come from the RefLocation assigned," typically occurs in the context of SAP's Industry Solution for Utilities (IS-U) when dealing with measurement points and reference locations. This error indicates that there is a mismatch between the measurement point you are trying to use and the reference location that has been assigned to it.
Cause: Incorrect Assignment: The measurement point you are trying to reference is not correctly assigned to the reference location in the system. Data Inconsistency: There may be inconsistencies in the master data, such as the measurement point being linked to a different reference location than expected.
Configuration Issues: There could be configuration issues in the system that prevent the correct association of measurement points and reference locations.
Solution: Check Measurement Point Assignment: Go to the transaction code for managing measurement points (e.g., EL31 or EL32). Verify that the measurement point is correctly assigned to
Get instant SAP help. Sign up for our Free Essentials Plan.
IR184
Reference MeasPoint does not come from the construction type allocated
What causes this issue? The current <DS:GLOS.measuring_point>measuring point</> or the measuring point to be created belongs to a piece o...
IR183
Equipment MeasPoints can only refer to construction type RefMeasPoints
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
IR186
RefMeasPoint has a different dimension -> assignment not possible
What causes this issue? You are trying to assign the current <DS:GLOS.measuring_point>measuring point</> a different reference measuring ...
IR200
No transfer of measurement/counter readings was defined
What causes this issue? The system has given you a list of proposals for the transfer of <DS:GLOS.measurement_reading>measurement readings</...
Click on this link to search all SAP messages.