Do you have any question about this error?
Message type: E = Error
Message class: ILM_STOR -
Message number: 675
Message text: Area &1 cannot be calculated and excluded at the same time
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
ILM_STOR675
- Area &1 cannot be calculated and excluded at the same time ?The SAP error message ILM_STOR675, which states "Area &1 cannot be calculated and excluded at the same time," typically occurs in the context of Information Lifecycle Management (ILM) when there is an issue with the configuration of data archiving or retention management.
Cause:
This error arises when there is a conflict in the settings for a specific area (denoted as &1 in the error message) in the ILM configuration. Specifically, it indicates that the system is trying to perform two contradictory actions simultaneously: calculating the data for retention or archiving while also excluding it from the process. This can happen due to:
- Configuration Issues: The ILM area may be incorrectly configured, leading to conflicting settings.
- Data Selection Criteria: The selection criteria for the data to be archived or retained may be set in a way that causes overlap or contradiction.
- Process Execution: The process that is being executed may not be aligned with the intended actions for the ILM area.
Solution:
To resolve this error, you can take the following steps:
Check ILM Configuration:
- Go to the ILM configuration settings in your SAP system.
- Verify the settings for the specific area mentioned in the error message. Ensure that the area is not set to be both calculated and excluded at the same time.
Review Data Selection Criteria:
- Examine the selection criteria used for the archiving or retention process. Make sure that the criteria do not conflict with the exclusion settings.
Adjust Process Execution:
- If you are running a specific ILM process (like archiving or retention management), ensure that the process is correctly set up to either calculate or exclude, but not both.
Consult Documentation:
- Refer to the SAP documentation for ILM to understand the specific configurations and settings for the area in question.
Testing:
- After making adjustments, test the process again to ensure that the error does not reoccur.
Seek Support:
- If the issue persists, consider reaching out to SAP support or consulting with an SAP expert who specializes in ILM for further assistance.
Related Information:
By following these steps, you should be able to identify and resolve the cause of the ILM_STOR675 error in your SAP system.
Get instant SAP help. Start your 7-day free trial now.
ILM_STOR674
Context origin already set, duplicate use not possible
What causes this issue? Each request is sent in the context of an origin. You can use only one origin per request or procedure. In this case, there w...
ILM_STOR673
Method cannot be called here, use &1 instead
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
ILM_STOR676
Status &1 invalid for HANDLE &2, &3 is expected
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
ILM_STOR677
BAdI implementation &1 not permitted in productive systems
What causes this issue? BAdI implementation &syst-msgv1& was called as delivered by SAP. This BAdI implementation enables faster testing on n...
Click on this link to search all SAP messages.