Do you have any question about this error?
Message type: E = Error
Message class: ILM_STANDARDS - ILM Standard Checks
Message number: 019
Message text: Time reference &1 (dynamic registration): Not defined in Customizing
You have defined time references for the ILM object by using the BAdIs
which were intended for them (this means not in transaction IRM_CUST).
The time references have not been defined as constants in the higher
level Customizing (section <LS>Time References for Start Determination
</> in transaction IRM_CUST). &V1& &V2& &V3& &V4&
INCLUDE ILM_STNDRD_CHECK_SYS_RESP_1 OBJECT DOKU ID TX
In the higher level Customizing (section <LS>Time References for Start
Determination</> in transaction IRM_CUST), define a constant for these
time references.
INCLUDE ILM_STNDRD_CHECK_WHATODO_1 OBJECT DOKU ID TX
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
ILM_STANDARDS019
- Time reference &1 (dynamic registration): Not defined in Customizing ?The SAP error message ILM_STANDARDS019 indicates that there is a problem with the time reference that is being used for dynamic registration in the Information Lifecycle Management (ILM) module. Specifically, it states that the time reference specified (denoted as
&1
) is not defined in the Customizing settings.Cause:
The error typically arises due to one of the following reasons:
- Missing Configuration: The time reference that is being referenced in the ILM process has not been defined in the Customizing settings.
- Incorrect Time Reference: The time reference being used may be incorrect or misspelled.
- Transport Issues: If the configuration was transported from another system, it may not have been properly imported or may be missing.
Solution:
To resolve this error, you can follow these steps:
Check Customizing Settings:
- Go to the Customizing transaction (SPRO).
- Navigate to the ILM settings and check the configuration for time references.
- Ensure that the time reference you are trying to use is defined correctly.
Define the Time Reference:
- If the time reference is missing, you will need to create it.
- In the ILM Customizing, look for the section related to time references and add the necessary entries.
Verify the Time Reference:
- Ensure that the time reference you are using in your ILM process matches exactly with what is defined in the Customizing settings.
- Check for any typos or discrepancies.
Transport Issues:
- If the configuration was recently transported, verify that the transport was successful and that all necessary objects were included.
- If needed, re-transport the configuration or manually adjust it in the target system.
Consult Documentation:
- Refer to SAP documentation or notes related to ILM and time references for additional guidance and best practices.
Related Information:
SPRO
for Customizing, ILM
for ILM-related activities, and SE11
for checking data dictionary objects.By following these steps, you should be able to resolve the ILM_STANDARDS019 error and ensure that your ILM processes function correctly.
Get instant SAP help. Start your 7-day free trial now.
ILM_STANDARDS018
Time reference &1: Not defined in Customizing
What causes this issue? According to transaction IRM_CUST, you have entered the following time references, which have not been defined as constants i...
ILM_STANDARDS017
Time reference &1, indirect value determin.: BAdI implementation missing
What causes this issue? According to transaction IRM_CUST, you have entered an indirect value determination for a time reference for the ILM object. ...
ILM_STANDARDS020
Time ref. &1: You need to define time references dynam. or statically
What causes this issue? The following time references have been registered for the ILM object in transaction IRM_CUST as well as for use with the BAd...
ILM_STANDARDS021
Time ref. &1: Obj. categ.-spec. registr. for value deter. missing (stat.)
What causes this issue? According to transaction IRM_CUST, you have defined the following time references for the ILM object. However, you have not y...
Click on this link to search all SAP messages.