Do you have any question about this error?
Message type: E = Error
Message class: IE - SAPLIEL2: Equipment hierarchies
Message number: 053
Message text: Stock check indicator change! Check settings for serialization procedures
Changing the stock check indicator can result in inconsistencies in the
settings for the serialization procedures.
Check these settings for the serial number profile in the Detail
screen.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Furthermore, you should check whether changing the stock check
indicator should also affect existing serial numbers.
In a productive system, this is strongly recommended. You can execute
<DS:REPO.RISERNR9>program RISERNR9</> to trace changes for existing
serial numbers. You should read the accompanying program documentation.
Error message extract from SAP system. Copyright SAP SE.
IE053
- Stock check indicator change! Check settings for serialization procedures ?The SAP error message "IE053 Stock check indicator change! Check settings for serialization procedures" typically occurs in the context of inventory management and serialization in SAP. This error indicates that there is an issue with the stock check indicator related to serialized materials. Here’s a breakdown of the cause, potential solutions, and related information:
Cause:
- Stock Check Indicator Change: The error suggests that there has been a change in the stock check indicator for a material that is serialized. This can happen if the settings for the material have been modified in a way that conflicts with existing stock or serialization procedures.
- Serialization Procedures: The serialization procedures defined in the system may not align with the current settings of the material. This can occur if the material was previously set up for serialization and the stock check indicator was changed to a non-serialized setting or vice versa.
- Configuration Issues: There may be configuration issues in the material master or in the serialization settings that need to be addressed.
Solution:
Check Material Master Settings:
- Go to the material master record (transaction code MM03) and check the settings for the stock check indicator and serialization.
- Ensure that the stock check indicator is correctly set according to the business requirements and that it matches the serialization settings.
Review Serialization Procedures:
- Check the serialization procedures defined in the system (transaction code OIS2 for serialization procedures).
- Ensure that the procedures are correctly configured and that they align with the stock check indicators for the materials in question.
Adjust Stock Check Indicator:
- If the stock check indicator needs to be changed, ensure that it is done in a way that does not conflict with existing stock. This may involve adjusting the stock or re-evaluating the serialization requirements.
Consult Documentation:
- Review SAP documentation or help resources related to serialization and stock management to ensure compliance with best practices.
Testing:
- After making changes, perform tests to ensure that the error does not reoccur and that the system behaves as expected.
Consult SAP Support:
- If the issue persists, consider reaching out to SAP support for further assistance, especially if it involves complex configurations or customizations.
Related Information:
By following these steps, you should be able to identify the cause of the error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
IE052
Stock check indicator and serial number check are inconsistent
What causes this issue? You have performed settings in the serial number profile that result in an error message being issued if inconsistencies are ...
IE051
Project transfer indicator is maintained for order type & -> Long text
What causes this issue? This setting is only advisable if you have set the indicator for transferring the number of the capital investment program fo...
IE054
Profile '&1' has stock check indicator '2'. The entry is not saved.
What causes this issue? A <DS:DE.BSTVP>stock check indicator</> that triggers an error message if no serial number &V1& stock is ...
IE055
Consistency check for serial number usage found an error. See long text.
What causes this issue? Please note that special rules exist for the operations PPAU and PPRL. The indicators for serial number usage for both the ke...
Click on this link to search all SAP messages.