Do you have any question about this error?
Message type: E = Error
Message class: ICL2 - FS-CM: Claims Management
Message number: 171
Message text: Screen field &1 not assigned to any field of the internal GUI structure
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
The system is unable to execute the required field check.
Temporarily remove your required field definition for screen field &v1&
Make a note of the name of the screen field and contact SAP if screen
field &v1& is a screen field delivered by SAP.
Error message extract from SAP system. Copyright SAP SE.
ICL2171
- Screen field &1 not assigned to any field of the internal GUI structure ?The SAP error message ICL2171, which states "Screen field &1 not assigned to any field of the internal GUI structure," typically occurs in the context of SAP's Interactive Forms or when working with custom screens in SAP GUI. This error indicates that a specific screen field (denoted by &1) is not properly mapped to any field in the underlying data structure that the screen is supposed to represent.
Cause:
- Field Mapping Issues: The field in question may not be correctly mapped to the data structure in the program or module pool. This can happen if the field was removed or renamed in the underlying data structure but not updated in the screen definition.
- Screen Configuration Errors: If the screen was modified (e.g., fields added or removed) without updating the associated data dictionary or program logic, it can lead to this error.
- Custom Development: In custom developments, if the screen fields are not properly defined or linked to the corresponding data elements, this error can occur.
Solution:
Check Field Mapping: Verify that the field mentioned in the error message is correctly defined in the screen's flow logic and is mapped to a corresponding field in the data structure. You can do this by:
- Going to the screen painter (SE80 or SE41) and checking the screen layout.
- Ensuring that the field exists in the data dictionary (SE11) and is correctly linked to the screen.
Update Screen Definition: If the field has been removed or renamed, update the screen definition to reflect the current data structure. This may involve:
- Modifying the screen layout to remove or replace the field.
- Ensuring that the field is included in the program logic that populates the screen.
Check Program Logic: Review the ABAP code associated with the screen to ensure that it correctly handles the data for the fields. Look for any logic that populates or processes the screen fields.
Transport Requests: If changes were made in a development environment, ensure that they are properly transported to the quality or production environment.
Debugging: If the issue persists, consider using the debugger to trace the program execution and identify where the field mapping is failing.
Related Information:
By following these steps, you should be able to identify and resolve the cause of the ICL2171 error in your SAP environment.
Get instant SAP help. Start your 7-day free trial now.
ICL2170
&1: Field &2 is a required field
What causes this issue? The settings in customizing are such that field &V2& with the short name "&V3&" is a required field...
ICL2169
Select at least one entry with a subclaim that is greater than 0
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
ICL2172
Use "+" for generic entries
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
ICL2173
Generic character for scrn field and GUI struct.fld must be simultaneous
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.