Do you have any question about this error?
Message type: E = Error
Message class: GW - Message Texts for Gateway
Message number: 762
Message text: SNC_LIB not defined in command line nor in environment
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
GW762
- SNC_LIB not defined in command line nor in environment ?The SAP error message GW762 indicates that the SNC (Secure Network Communications) library is not defined in the command line or in the environment. This error typically occurs when you are trying to start an SAP instance that requires SNC but the necessary configuration for the SNC library is missing.
Cause:
- SNC Not Configured: The SNC library is not specified in the command line or environment variables when starting the SAP instance.
- Missing SNC Library: The required SNC library files may not be installed or accessible in the expected directory.
- Incorrect Environment Variables: The environment variables related to SNC may not be set correctly.
Solution:
To resolve the GW762 error, you can follow these steps:
Check SNC Configuration:
- Ensure that SNC is properly configured in your SAP system. This includes checking the profile parameters related to SNC in the instance profile (e.g.,
snc/enable
,snc/lib
, etc.).Set Environment Variables:
- You need to set the
SNC_LIB
environment variable to point to the correct SNC library. This can be done in the command line or in the environment settings of your operating system.- For example, in a Unix/Linux environment, you can set it like this:
export SNC_LIB=/path/to/your/snc/library
- In Windows, you can set it in the system environment variables.
Modify the Start Command:
- If you are starting the SAP instance from the command line, you can specify the SNC library directly in the command. For example:
startsap <instance> SNC_LIB=/path/to/your/snc/library
Check Library Installation:
- Ensure that the SNC library is installed on your system. If it is not installed, you may need to download and install it from the SAP Service Marketplace or your SAP installation media.
Review SAP Notes:
- Check for any relevant SAP Notes that may provide additional guidance or updates related to SNC configuration and troubleshooting.
Restart the SAP Instance:
- After making the necessary changes, restart the SAP instance to apply the new configuration.
Related Information:
By following these steps, you should be able to resolve the GW762 error and successfully start your SAP instance with SNC enabled.
Get instant SAP help. Start your 7-day free trial now.
GW761
Communication system error; receive failed; check partner
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
GW757
Client has not answered PING messages and was logged out.
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
GW763
SNC_NAME not defined in command line nor in environment
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
GW764
Invalid SNC handle
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.