Do you have any question about this error?
Message type: E = Error
Message class: GLPL - Message class planning FI-SL/GL
Message number: 103
Message text: The combination of ledger &1 and global company &2 is not entered
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
GLPL103
- The combination of ledger &1 and global company &2 is not entered ?The SAP error message GLPL103 indicates that there is an issue with the configuration of the ledger and global company combination in the system. This error typically arises when you attempt to perform a transaction or access data that requires a specific ledger and global company combination that has not been defined in the system.
Cause:
- Missing Configuration: The specified combination of ledger and global company has not been set up in the system.
- Incorrect Input: The ledger or global company entered in the transaction does not match any existing configuration.
- Data Migration Issues: If data has been migrated from another system, the necessary configurations may not have been transferred correctly.
- Authorization Issues: The user may not have the necessary authorizations to access the specified ledger or global company.
Solution:
Check Configuration:
- Go to the configuration settings in SAP and verify that the combination of the ledger and global company is correctly defined.
- You can check this in the following path:
- SPRO ? Financial Accounting ? General Ledger ? Global Settings ? Ledgers ? Define Ledgers.
- Ensure that the ledger you are trying to use is assigned to the global company.
Create Missing Combination:
- If the combination does not exist, you may need to create it. This can be done in the same configuration area mentioned above.
Verify Input:
- Double-check the input values for the ledger and global company in the transaction you are trying to execute. Ensure that they are correct and match the defined combinations.
Check Authorizations:
- Ensure that the user has the necessary authorizations to access the specified ledger and global company. This can be checked with your SAP security team.
Consult Documentation:
- Review SAP documentation or help resources for any additional context or specific steps related to your version of SAP.
Contact Support:
- If the issue persists after checking the above points, consider reaching out to SAP support or your internal IT support team for further assistance.
Related Information:
OB22
(for defining ledgers) or OBY6
(for defining global companies) to access the relevant configuration settings.By following these steps, you should be able to resolve the GLPL103 error and ensure that the necessary configurations are in place for your SAP system.
Get instant SAP help. Start your 7-day free trial now.
GLPL102
The combination of ledger &1 and company code &2 is not entered
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
GLPL101
Summary table &2 for ledger &1 not available
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
GLPL104
The combination layout-profile was read
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
GLPL105
The combination of profile, item, and layout already exists
What causes this issue? You have selected a combination of profile, layout, and item which already exists.System Response The planning tool cannot u...
Click on this link to search all SAP messages.