Do you have any question about this error?
Message type: E = Error
Message class: GK - Messages for SAP Consolidation
Message number: 670
Message text: System utilization not maintained for consolidation of investments.
System utilization for consolidation of investments has not been
maintained for dimension &V1&.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
GK670
- System utilization not maintained for consolidation of investments. ?The SAP error message GK670, which states "System utilization not maintained for consolidation of investments," typically occurs in the context of SAP's Financial Consolidation module, particularly when dealing with investment consolidations. This error indicates that the system does not have the necessary configuration or data to perform the consolidation of investments.
Cause:
- Missing Configuration: The system utilization settings for the consolidation of investments have not been maintained in the system.
- Incorrect Settings: The settings may be incorrectly configured or not aligned with the requirements for the investment consolidation process.
- Data Inconsistencies: There may be inconsistencies or missing data in the master data related to the investments or the entities involved in the consolidation.
Solution:
To resolve the GK670 error, you can follow these steps:
Check Configuration:
- Navigate to the configuration settings for the consolidation of investments in the SAP system.
- Ensure that the system utilization for the relevant investment consolidation is properly maintained. This can typically be found in the Customizing settings under Financial Consolidation.
Maintain System Utilization:
- Go to the transaction code
OB58
or the relevant path in the SAP menu to maintain the system utilization settings.- Ensure that the necessary parameters for the consolidation of investments are filled out correctly.
Review Master Data:
- Check the master data for the entities involved in the consolidation. Ensure that all necessary data is complete and accurate.
- Verify that the investment accounts and related entities are correctly set up in the system.
Consult Documentation:
- Refer to the SAP documentation or help files related to investment consolidation for specific guidelines on maintaining system utilization.
Testing:
- After making the necessary changes, perform a test run of the consolidation process to ensure that the error is resolved.
Seek Help from SAP Support:
- If the issue persists after following the above steps, consider reaching out to SAP support for further assistance. They may provide insights specific to your system configuration.
Related Information:
OB58
, KSV5
, or others related to investment consolidation.By following these steps, you should be able to address the GK670 error and successfully maintain the system utilization for the consolidation of investments in SAP.
Get instant SAP help. Start your 7-day free trial now.
GK669
The treatment of negative goodwill must be chosen.
What causes this issue? Various elimination options are available for the treatment of <DS:GLOS.negative_goodwill>negative goodwill</> as...
GK668
One or more cons groups do not have any cons unit assignments
What causes this issue? At least one consolidation unit must be assigned (directly or indirectly) to a given consolidation group. The following conso...
GK671
C/I methods &1 do not exist
What causes this issue? The following consolidation of investment (C/I) methods (among others) have been assigned to the consolidation units: &V1...
GK672
The global method attribute '&1' not maintained for dimension &2
What causes this issue? The global method attribute &V1& has not been maintained for dimension &V2&.System Response The system issue...
Click on this link to search all SAP messages.