Do you have any question about this error?
Message type: E = Error
Message class: GC - Error Messages for Consolidation/Extended General Ledger
Message number: 190
Message text: Only one unit of measure allowed within an elimination set
Within elimination set &V1& both quantities of unit &V2& and &V3&
exist.
IC elimination cannot eliminate quantities.
When defining elimination sets ensure that each one only contains FS
items with data for one unit of measure.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
GC190
- Only one unit of measure allowed within an elimination set ?The SAP error message GC190, which states "Only one unit of measure allowed within an elimination set," typically occurs in the context of financial consolidation processes, particularly when dealing with elimination sets in SAP Financial Consolidation (FC) or SAP Business Planning and Consolidation (BPC).
Cause:
This error arises when there are multiple units of measure defined for a single elimination set. An elimination set is used to eliminate intercompany transactions to avoid double counting in consolidated financial statements. However, SAP requires that each elimination set can only have one unit of measure to ensure consistency and accuracy in the elimination process.
Solution:
To resolve the GC190 error, you can take the following steps:
Review Elimination Set Configuration:
- Go to the configuration settings for the elimination set in your SAP system.
- Check the units of measure assigned to the elimination set. Ensure that only one unit of measure is defined.
Modify the Elimination Set:
- If you find multiple units of measure, you will need to modify the elimination set to include only one.
- You can either remove the additional units of measure or create separate elimination sets for different units of measure if necessary.
Check Related Master Data:
- Review the master data for the entities involved in the elimination. Ensure that they are consistent in terms of the unit of measure used.
Test the Changes:
- After making the necessary adjustments, run the consolidation process again to verify that the error has been resolved.
Consult Documentation:
- Refer to SAP documentation or help resources for specific guidance on managing elimination sets and units of measure.
Related Information:
By following these steps, you should be able to resolve the GC190 error and ensure that your elimination sets are configured correctly for financial consolidation.
Get instant SAP help. Start your 7-day free trial now.
GC189
Data was saved
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
GC188
Transaction type set & for table & not defined (elimination set &)
What causes this issue? The transaction type set of the specified elimination set was not found.System Response Program abortHow to fix this error? ...
GC191
No ledger for consolidation has been specified
What causes this issue? No consolidation staging ledger was allocated to the company code.System Response If an extract is to be created for consoli...
GC192
Assignment made for realtime update to the cons.proc./cons.staging ledger
What causes this issue? The following assignments for updating are made:System Response Setup "Realtime Update": All company codes to whic...
Click on this link to search all SAP messages.