Message type: E = Error
Message class: GBW - SAP Consolidation interface to BW
Message number: 004
Message text: 'Data Streams from BW' cannot be selected for this entry
In the higher-level subdialog ''Destination'' an entry is selected for
which the reading indicator is not set. You cannot select the subdialog
''Data flows from BW'' for this entry.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Select a different entry from the higher-level subdialog
''Destination'', where the reading indicator is set. Alternatively you
can set the reading indicator for the entry that is currently selected.
Error message extract from SAP system. Copyright SAP SE.
The SAP error message GBW004, which states that "Data Streams from BW cannot be selected for this entry," typically occurs in the context of SAP BW (Business Warehouse) when there is an issue with the data stream configuration or selection criteria. Causes: Incorrect Data Stream Configuration: The data stream may not be properly configured in the BW system, leading to the inability to select it for the entry. Missing Authorizations: The user may not have the necessary authorizations to access the data stream. Data Stream Not Active: The data stream might not be active or available for selection in the current context. Incompatible Data Model: The data model or structure may not support the selected data stream. Technical Issues: There could be underlying technical issues, such as system inconsistencies or errors in the BW system. Solutions: Check Data Stream Configuration: Verify that the data stream is correctly configured in the BW system. Ensure that all necessary settings are
Get instant SAP help. Sign up for our Free Essentials Plan.
GBW003
'Data Streams to BW' cannot be selected for this entry
What causes this issue? In the higher-level subdialog ''Destination'' an entry is selected which has the reading indicator set. Y...
GBW002
Direct navigation to 'Further Selections' not possible
What causes this issue? You can only get to the subdialog 'More selections' from the subdialog 'Data flows from BW'.System Respon...
GBW005
No connection could be established with target system &1
What causes this issue? A connection to target system &V1& could not be established.System Response Process was canceled.How to fix this err...
GBW006
InfoCube &2 in target system &1 does not exist active
What causes this issue? InfoCube &V2& in target system &V1& is not active.System Response The action was canceled.How to fix this er...
Click on this link to search all SAP messages.