Message type: E = Error
Message class: G00 - SAP Consolidation
Message number: 758
Message text: Field &1: Value from header row overwritten by control row
You have defined the &V1& field multiple times:
In the header row of the upload file
In the control row of the upload file with row type indicator D for the
column structure of the data rows
The system ignores the value for the &V1& field that you defined in the
header row of the upload file and transfers instead the values from the
column in the data rows that you marked in the control row with the
semantic field name for the &V1& field
Adjust the definition of the header row in the upload method as
necessary.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
G00758
- Field &1: Value from header row overwritten by control row ?The SAP error message G00758, which states "Field &1: Value from header row overwritten by control row," typically occurs in the context of data uploads or data processing in SAP, particularly when dealing with data from external sources like spreadsheets or flat files. This error indicates that there is a conflict between the values in the header row and the control row of the data being processed.
Cause: Data Conflict: The error arises when the value in the control row (which is often used for validation or control purposes) is different from the value in the header row. The control row is usually the first row of data that contains specific values that are meant to validate or control the data being processed. Incorrect Data Format: The data being uploaded may not conform to the expected format, leading to discrepancies between the header and control rows.
Configuration Issues: There may be issues with the
Get instant SAP help. Sign up for our Free Essentials Plan.
G00757
Control row &1 in upload file: Positioning with errors
What causes this issue? You are using various control rows in the current upload file. You have marked these with the following row type indicators: ...
G00756
Selected item: full goodwill: item &1 has incorrect partner breakdown
What causes this issue? Items for full goodwill require an optional breakdown by partners for the system to be able to distribute the full goodwill t...
G00759
Dialog box skipped in current upload
What causes this issue? In the upload method, you have defined for some fields that input is interactive using a dialog box. In the current upload fi...
G00771
Dimension &1: No document type exists for realtime update
What causes this issue? You have executed the validation for the following parameters: Dimension &V1& Valuation <LS>Universal Documents...
Click on this link to search all SAP messages.