Do you have any question about this error?
Message type: E = Error
Message class: FRMLSCN - RMS-FRM: Data Retrieval for Contribution and Comp.from Spec.
Message number: 035
Message text: No component type exists for substance &1 and value assignment type &2
No component type exists for substance &V1& and value assignment type
&V2&.
Values are not written to the specification database.
In Customizing for EH&S, enter a component type for object category
SUBSTANCE, context parameter SUB_COMP_STD_DIALOG, and value assignment
type &V2& in the
<DS:SIMG.EHS_MD_130_30_2>Specify Context-Specific Component Types</>
activity.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
FRMLSCN035
- No component type exists for substance &1 and value assignment type &2 ?The SAP error message FRMLSCN035 indicates that there is an issue with the configuration of a substance in the SAP system, specifically related to the component type and value assignment type. This error typically arises in the context of SAP's Product Safety and Compliance (PSC) module, which deals with the management of hazardous substances and compliance with regulations.
Cause:
The error message FRMLSCN035 is triggered when the system cannot find a valid component type for the specified substance and value assignment type. This can occur due to several reasons:
- Missing Configuration: The component type for the substance has not been defined in the system.
- Incorrect Substance Definition: The substance may not be correctly defined or may not exist in the system.
- Value Assignment Type Issues: The value assignment type specified may not be valid for the given substance.
- Data Inconsistency: There may be inconsistencies in the data related to the substance or its configuration.
Solution:
To resolve the FRMLSCN035 error, you can take the following steps:
Check Substance Definition:
- Go to the substance management area in SAP and verify that the substance in question is correctly defined.
- Ensure that the substance has the appropriate component type assigned.
Verify Component Type:
- Check if the component type for the substance is defined in the system. You can do this by navigating to the relevant configuration settings in the SAP system.
- If the component type is missing, you may need to create it or assign an existing one.
Review Value Assignment Types:
- Ensure that the value assignment type you are using is valid for the substance. You can check the configuration for value assignment types in the system.
- If necessary, modify the value assignment type to one that is compatible with the substance.
Consult Documentation:
- Review SAP documentation or help resources related to substance management and value assignment types for additional guidance.
Check for Updates:
- Ensure that your SAP system is up to date with the latest patches and updates, as this may resolve known issues related to substance management.
Contact SAP Support:
- If the issue persists after checking the above points, consider reaching out to SAP support for further assistance. They may provide insights specific to your system configuration.
Related Information:
C223
(Define Component Types) and C201
(Define Value Assignment Types) to manage and configure substances.By following these steps, you should be able to identify and resolve the cause of the FRMLSCN035 error in your SAP system.
Get instant SAP help. Start your 7-day free trial now.
FRMLSCN033
Unit of meas. &1 not allowed for composition (substance &2, component &3)
What causes this issue? The unit of measurement &V1& has a dimension that is not permitted.System Response The system issues an error messag...
FRMLSCN032
No density exists
What causes this issue? You have selected 100 ml as the calculation base. The system needs the value you specified for the density in the relevant fo...
FRMLSCN036
Enter the unit for the portion size in the formula property tree
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
FRMLSCN037
Enter the portion size unit in the property tree for the primary output
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.