Do you have any question about this error?
Stop googling SAP errors. Use our Free Essentials plan instead - no credit card needed. Start Now →
Message type: E = Error
Message class: FRMLMSC - RMS-FRM: Miscellaneous Messages for Formula
Message number: 151
Message text: No usage profile exists for value assignment type &1
To read specification data for calculating, for example, density, total
solids, or compositions, and for saving the calculated properties in the
property tree of the formula, the system requires a usage. You can
specify this usage for the relevant view in Customizing. If no entry
exists in Customizing, the system takes the usage from the usage profile
of the appropriate value assignment type.
No usage profile exists for value assignment type &1.
The system cannot read the data and cannot save it.
Assign a usage profile with a usage to the value assignment type.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
FRMLMSC151
- No usage profile exists for value assignment type &1 ?The SAP error message FRMLMSC151 indicates that there is no usage profile defined for the specified value assignment type in the system. This error typically occurs in the context of SAP's Product Lifecycle Management (PLM) or Material Management (MM) modules, particularly when dealing with classification and characteristics in material master data or when working with formulas in the context of recipe management.
Cause:
- Missing Usage Profile: The primary cause of this error is that the system is trying to access a value assignment type that does not have an associated usage profile defined in the system.
- Configuration Issues: There may be configuration issues in the system where the value assignment type is not properly set up or linked to a usage profile.
- Data Inconsistencies: There could be inconsistencies in the data where the value assignment type is referenced but not properly configured.
Solution:
To resolve the FRMLMSC151 error, you can follow these steps:
Check Value Assignment Type:
- Identify the value assignment type indicated in the error message (represented by &1).
- Go to the relevant configuration settings in SAP to check if a usage profile exists for this value assignment type.
Define Usage Profile:
- If no usage profile exists, you will need to create one. This can typically be done in the following way:
- Navigate to the configuration transaction (usually in SPRO).
- Go to the section for defining usage profiles for value assignment types.
- Create a new usage profile and link it to the value assignment type.
Assign Usage Profile:
- Ensure that the newly created usage profile is correctly assigned to the relevant value assignment type.
- Make sure that all necessary characteristics and attributes are included in the usage profile.
Check for Data Consistency:
- After making changes, check for any inconsistencies in the data that might still be causing issues.
- Validate that all materials or recipes using this value assignment type are updated accordingly.
Testing:
- After making the necessary changes, perform tests to ensure that the error no longer occurs when trying to use the value assignment type.
Related Information:
SPRO
for configuration, CT04
for characteristics, or C223
for value assignment types.By following these steps, you should be able to resolve the FRMLMSC151 error and ensure that your value assignment types are properly configured in SAP.
Get instant SAP help. Sign up for our Free Essentials Plan.
FRMLMSC150
No entries or several entries exist for usage profile &1
What causes this issue? To read specification data for calculating, for example, density, total solids, or compositions, and to save the calculated p...
FRMLMSC149
Substance &1, accuracy loss due to reduced number of decimal places
What causes this issue? Accuracy may be lost when the system converts 6 decimal places to 4.System Response The system performs the conversion to th...
FRMLMSC152
No density (aeration) is specified for specification &1
What causes this issue? The system issues an error message and will not allow you to continue with this transaction until the error is resolved. Syst...
FRMLMSC153
Lot sizes were reset
What causes this issue? The base quantity is not within the lot-size interval.System Response To avoid problems as a result of this, the system rese...